抗震设防烈度对多层混凝土结构性能的影响
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
针对多层混凝土结构底层柱抗震能力较差的问题,本文采取提高结构的抗震设防烈度方法,计算分析七度、八度设防下框架梁、柱的轴力、剪力和弯矩。数值结果表明:提高结构的设防烈度,梁、柱的弯矩、剪力、轴力均增大,在底层(第一层)变化最为突出。地震作用下,结构的破坏形式主要表现为底层柱的破坏,因而增大建筑设计中的设防烈度可从根本上解决这一问题。
For multilayer concrete structure,the seismic ability of the ground floor column is very poor,improving the seismic fortification intensity of structure is adopted in this paper,the axial force,shear and moment of beam and column are calculated and analyzed in seven degree and eight degree seismic fortification intensity.Numerical results show that with improving the fortification intensity of the structure,the axial force,shear and moment of beam and column increase and the change of the ground floor is the most prominent.In earthquake the destruction of the structure mainly happens in the ground floor column,so this problem is solved fundamentally with increasing fortification intensity in architectural design.
引文
[1]罗艳.建筑抗震设防标准优化方法的基础研究[D].中国海洋大学,2009.
    [2]赵宏旭.高层建筑结构隔震减震技术研究[J].湖南科技学院学报,2009,30(8):150-151.
    [3]江宜诚,唐家祥.多层框架隔震结构的地震扭转反应分析[J].工程抗震,2000,13(2):12-14.
    [4]周福霖.工程结构减震控制[M].北京:地震出版社,1997.
    [5]陈昱.建筑结构隔震技术研究[J].山西建筑,2009,35(7):67-68.
    [6]谢礼立.2008年汶川特大地震的教训[J].中国工程科学,2009,11(6):28-35.
    [7]王亚勇.概论汶川地震后我国建筑抗震设计标准的修订[J].土木工程学报,2009,42(5):1212.
    [8]李秀珍,邓红艳.“5.12”汶川地震滑坡特征及失稳破坏模式分析[J],四川大学学报:工程科学版,2009,41(3):72-77.
    [9]Wen Y K,Kang Y J.Minimum building life-cycle cost designcriteria,Ⅰ:Methodology andⅡ:Application[J].Journal ofStructural Engineering,2001:127(3):330-346.
    [10]中国建筑科学研究院.2008年汶川地震建筑震害图片集[M].中国建筑工业出版社,2008:80-114.
    [11]苏幼坡,刘瑞兴.城市地震避难所的规划原则与要点[J].灾害学,2004,19(1):87-91.
    [12]GB50023—2009,建筑抗震鉴定标准[S].北京:中国建筑工业出版社,2009.
    [13]GB50223—2008,建筑工程抗震设防分类标准[S].北京:中国建筑工业出版社,2008.
    [14]中华人民共和国行业标准,混凝土结构设计规范.GB50010—2002[S].北京:中国建筑工业出版社,2002.