北京市人大办公楼的结构地震反应观测台阵研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
概述了国内外强震动观测的研究现状和结构地震反应观测台阵的研究情况。并对北京市人大办公楼的结构地震反应观测台阵的研究实例作了分析,该观测台阵在没有强震的情况下,依然取得了有用的地震记录。文中对该台阵得到的两次地震记录分析、处理,结果的对比分析用于验证该结构反应观测台阵布设的合理性。最后阐述了该台阵布设的不足,针对不足给出几点结构反应观测台阵布设的合理建议,并展望了结构地震反应观测台阵布设研究的美好前景。
The study situation of strong motion observation and structural seismic response observation is summarized. Analysis is based on a typical example of a structural seismic response observation array installed in the office building of the Standing Committee of Beijing People's Congress, which recorded useful seismic data in absence of strong motions. Two seismic data from this array are processed and analyzed. The results are compared to verifly the rationality of array. The defects in this array are also discussed and some proper suggestions are provided to instrument arrays. Finally it is pointed out that the researches on structural seismic response arrays have a brighter future.
引文
北京市地震局震害防御与工程地震研究所.1999.北京市人大办公大楼强震监测系统建设工程报告[R]
    李鸿晶,朱士云,Mehmet Celebi.2003.强震观测建筑结构的地震反应分析[J].地震工程与工程振动,23(6):31~33
    谢礼立,于双久.1982.强震观测与分析原理[M].北京:地震出版社,149~164
    尹之潜,彭克中.1962.建筑物脉动现象分析[M].见:地震工程研究报告集.北京:科学出版社,122~129
    周雍年.2001.强震观测的发展趋势和任务[J].世界地震工程,17(4):19~26
    周正华,李铁,戴志勇,吴惟廉等.2000.建筑结构地震反应观测系统[J].地球物理学进展,19(4):868~872
    Safak E and Celebi M. 1992. Recorded seismic response of Pacific Park Plaza: -Ⅱ, System identification[J]. Journal of Structural Engineering, 18(6):1566-1589