小尺度浅层瞬变电磁检测复合材料的实验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
针对碳纤维复合材料复杂的结构特点,借鉴地质勘探中的瞬变电磁法,提出小尺度浅层瞬变电磁法对复合材料进行检测。采用浅部瞬变电磁勘探系统,通过改进检测线圈结构并合理选择阻尼电阻,可以实现碳纤维复合材料的瞬变电磁检测。实验结果表明,剖面曲线主要异常的个数与实际缺陷的个数相同,而且异常宽度与缺陷大小的变化规律也是一一对应的。
To the complicated structural characteristic of carbon composites,the transient electromagnetic method(TEM)in the geology prospecting was used for reference,small yardstick and shallow TEM was put forward to measure composites.The TEM testing of carbon fibre composite material can be achieved by using shallow TEM exploration system,improving dection coil structure and reasonably selecting damping resistance.The experimental result indicates that main anomaly of profile curve has the same number as actual defect of test block,and anomalous width is consistent with defect size in change rule.
引文
[1]李志君.先进复合材料的无损检测.宇航材料工艺,2000(5):28-31.
    [2]WRIGHT D L.A VETEM survey of a former munitions foundry site atthe Denver Federal Center.Proceedings for SAGEEP’2000,Washing-ton D.C.,2000:459-468.
    [3]稽艳鞠.浅层高分辨率全程瞬变电磁系统中全程二次场提取技术研究:[学位论文].吉林:吉林大学,2004.
    [4]马静.浅层瞬变电磁信号采集与处理技术研究:[学位论文].重庆:重庆大学,2008.
    [5]王华军.阻尼系数对瞬变电磁观测信号的影响特征.地球物理学报,2010,53(2):428-434.
    [6]陈明生.二维地质体的瞬变电磁场响应特征.地震地质,2001,23(2):252-256.
    [7]王淑娟,赵再新,翟国富.基于电磁超声的火车车轮裂纹检测系统.仪表技术与传感器,2005(11):30-32.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心