等离子点火燃烧技术在电厂节能和环保方面的应用
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
介绍了等离子点火技术在浙江长兴电厂3号炉上的应用。自电厂进行等离子点火装置改造并正式投运以来,取得了良好的经济效益和节能效果,环境效益也十分显著,实现了低负荷断油燃烧,节油率达90%左右,1台300 MW机组可节约燃油成本180万元/a。
The application of plasma ignition combustion technique in the 3rd boiler of Zhejiang Changxing thermal power plant is introduced.Since the plasma ignition combustion have been remodified and put into operation,the economic benefit and energy conservation have been remarkable.The environmental benefit is also obvious.Though the technical remodification,the without oil combustion is realized and oil is saved about 90%.1.8 million Yuan oil cost can be saved for one 300MW unit every year.
引文
[1]国家电力工业部建设协调司.火电工程调整试运质量检验及评定标准(1996年版),(建质[1996]111号),1996-10.
    [2]邓庆松,周世平.300 MW火电机组调试技术[M].北京:中国电力出版社,2003.
    [3]路春美,王永征.煤燃烧理论与技术.[M].北京:地震出版社,2001.
    [4]胡兆光.加大节能降耗力度,全面完成“十一五”规划目标[J].中国电力,2006,(1):22-25.
    [5]张锡根.等离子点火燃烧技术在长兴电厂30万千瓦机组的应用,浙江能源,2006,(1):42-44.