FHD磁力仪分量线圈装置误差对磁偏角观测的影响分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
根据FHD磁力仪观测磁偏角的原理,计算了分量线圈不水平导致的磁偏角观测值误差,发现分量线圈仅在EW方向的倾斜对磁偏角观测产生误差。文中将理论分析结果与实际观测结果进行了对比分析,发现由于分量线圈底座水平的长期漂移,仪器的垂直分量及磁偏角观测误差也会发生长期漂移,长期漂移变化的周期约2~4个月,对垂直分量其幅度约3.5~11.0nT,而磁偏角的幅度约0.1′~1.0′,因此认为在将该仪器观测值用作绝对观测值进行地震异常分析时,应注意回避这种长期漂移变化
This paper studied the influence of the directional error of vector coil on the declination of FHG vector proton precession magnetometer in theory. The result indicates that only the directional error of the vector coil in east-west direction has the influence on the declination. This paper also analyzed the error of observation data with the theoretical result, and finds that there is long-period drift about the error of observation data of declination and horizontal intensity of this magnetometers with the drift of directional error of the vector coil. The estimated drift cycle ranges 2~4 months, the drift quantity of vertical intensity is about 3.5~11.0 nT, the declination is 0.1′~ 1.0′. The suggestion is also proposed that the drift must be avoided in analysis of seismomagnetic precursor.
引文
[1] 嵇才键,何祖椿,马森林,等.FHD 1型质子磁力仪研制报告[M].北京:地震出版社,1999.1 3.
    [2] 冯志生,杨冬梅,夏忠,等.分量核旋仪偏置电流对磁偏角测量的影响分析[J].地震,2002,22(2):60 66.
    [3] 国家地震局科技监测司.地震电磁观测技术[M].北京:地震出版社,1995.190 194.
    [4] 北京大学,中国科技大学地球物理教研室.地磁学教程[M].北京:地震出版社,1986.352 361.
    [5] 冯志生,王建宇,梅卫萍,等.江苏地区地磁Z21测值空间相关异常及其标志体系[J].地震地磁观测与研究,2000,21(1):44 49.
    [6] 冯志生,王建宇,蒋延林,等.地磁垂直分量日变幅度逐日比及其与地震关系的探讨[J].华南地震,2001,21(2):20 27.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心