砖混教学楼纵向窗间墙抗震性能试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
通过5片砖混教学楼纵向窗间墙试件的拟静力试验,分别对配置不同尺寸和不同配筋率构造柱的窗间墙试件的破坏形态、滞回性能、变形能力等进行了试验分析。研究结果表明,构造柱的尺寸和配筋率对窗间墙的抗震性能影响较大,增大构造柱截面尺寸但保持较低的配筋率可显著改善窗间墙的抗震性能,但构造柱配筋增大到一定程度后反而会降低窗间墙的变形能力。因此,适度增大构造柱尺寸并合理控制配筋率是砖混教学楼纵向窗间墙抗震设计的关键。
Quasi-static tests on five specimens were conducted to investigate the seismic performance of longitudinal wall between windows of brick-concrete school building.The seismic performance of longitudinal wall between windows with different size and reinforcement ratio of structural column was investigated respectively,including damage characteristics,hysteresis behavior and deformation capacity of specimens.The results indicate that the section size and reinforcement ratio of structural column have significant effect on the seismic performance of specimens.Increasing the section size of structural column can improve the seismic performance of longitudinal wall between windows significantly.However,increasing reinforcement ratio of structural column to a certain extent will decrease deformation capacity of longitudinal wall between windows.Therefore,properly increasing the section size of structural column and reasonably controlling the reinforcement ratio are crucial important in the seismic design of longitudinal wall between windows of brick-concrete school building.
引文
[1]赵统,张新培,田志鹏.汶川地震中小学砖混结构教学楼震害特征分析[J].世界地震工程,2009,25(3):150-158.
    [2]徐有邻.汶川震害的教训——教学楼倒塌的反思[J].建筑结构,2009,39(11):50-53.
    [3]雷涛,李碧雄,顺远坤,等.汶川地震中绵竹市中小学校舍震害调查分析[J].建筑结构,2009,39(11):58-62.
    [4]李乔,赵世春.汶川大地震工程震害分析[M].成都:西南交通大学出版社,2008.
    [5]清华大学,西南交通大学,重庆大学,等.汶川地震建筑震害分析及设计对策[M].北京:中国建筑工业出版社,2009.
    [6]孙雪梅,刘伟庆.大开间约束砖砌体开窗洞墙片的拟静力试验研究[J].工程抗震,2004(2):31-34.
    [7]史庆轩,易文宗,刘伯权.多孔砖砌体开窗洞纵墙片的抗震性能研究[J].世界地震工程,2000,16(2):30-34.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心