连接体设置隔震消能部件的连体框架减振分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对一单轴对称框架结构,通过刚接、铰接以及连接体位置2种不同的隔震消能部件设置方式共4种连接方案,采用快速非线性分析方法(FNA),沿结构X、Y方向输入EI-Centro波,研究连体框架结构在连接方式变化时,结构抗震性能的变化。计算结果表明:连接体位置引入隔震消能部件能大幅减小结构在地震作用下的地震响应,提高结构的抗震性能。其中在连接体端部设置双向橡胶隔震支座与阻尼器的"柔性"连接,效果尤为显著。
Aseismic performance of a monosymmetrical double-frame structure is studied by the method of fast non-linear analysis(FNA) when the four types of connection patterns are changed.The results show that,the using of energy-consuming devices can significantly reduce the seismic response of structures under seismic action and improve the seismic performance of the monosymmetrical connected double-tower structure.The effect of setting the isolations and dampers at the end of the connection is more particularly significant than setting the isolations and dampers at the connection inside.
引文
[1]吴耀辉.大底盘双塔连体高层建筑的抗震与减振分析[D].南京:东南大学,2004.
    [2]Bhaskararao A V,Jangid R S.Seismic analysis ofstructures connected with friction dampers[J].Engi-neering Structures,2006,28(5):690-703.
    [3]北京金土木软件技术有限公司.SAP2000中文版使用指南[M].北京:人民交通出版社,2006.
    [4]陈文兵,唐家祥.水平任意向地震输入下双塔楼连体结构的动力分析[J].振动与冲击,2003,22(1):29-32.
    [5]吕西林,翁大根,周强.高层建筑组合消能减震体系研究与应用[A].中国土木工程学会第十届年会论文集[C].《土木工程与高新技术》中国建筑工业出版社,2002:69-73.
    [6]梁启智,孙文波.高层建筑互联结构间耗能减振器布置的优化[J].华南理工大学学报,1994,22(3):44-49.
    [7]范重,吴学敏.带有双塔楼高层建筑结构动力特性分析[J].建筑结构学报,1996,17(6):11-18.
    [8]周福霖.工程结构减震控制[M].北京:地震出版社,1997.
    [9]叶正强,李爱群,程文瀼,等.采用粘滞流体阻尼器的工程结构减振设计研究[J].建筑结构学报,2001,22(4):61-66.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心