火力发电厂脱硫塔结构简化模型等效刚度的研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
由于脱硫塔结构设计的复杂性,找到一种设计简化的模型是非常必要的,而简化模型的等效刚度是简化模型合理的重要条件。通过不同方法求得的等效刚度与有限元模型计算所得刚度进行比较,得出简化模型最合理的等效刚度,用于脱硫塔结构的动力计算。
Due to the complextiy of structure design of flue gas desulfuration absorbing tower,it is essential to find a simplified model,and the equivalent stiffness of smiplified model is the most important condition.We can educe equivalent stiffness of smiplified model and use it computing structure dynamics by comparing equivalent stiffness and practice stiffness.
引文
[1]张慧明.中国燃煤工业锅炉烟气脱硫的现状及发展趋势[C].中国SO2污染治理技术国际会议论文集,北京,1998.
    [2]Schmidt H,Binder B,Lange H.Postbuckling StrengthDesign of Open Thin-walled Cylindrical Tanks Under WindLoad[J].Thin-walled Structures,1998,31(1):203-220.
    [3]杨富贵.开孔薄壁圆筒在轴向压缩载荷下中间层的应力分量表达式[J].天津工业大学学报,2001,20(4):60-61.
    [4]Winterstetter Th A,Schmidt H.Stability of Circular Cy-lindrical Steel Shells Under Combined Loading[J].Thin-walled Structures,2002,40(10):893-909.
    [5]刘爱萍,陈志平,郑津洋.矩形大开孔的补强结构设计[J].压力容器,2001,18(4):46-49.
    [6]程昌钧,吕小安.开孔结构的稳定性分析及其应用[J].力学进展,1997,21(1):85-96.
    [7]吴连元.板壳稳定性理论[M].武汉:华中理工大学出版社,1996.
    [8]路秀林,王者相.化工设备设计全书-塔设备[M].北京:化学工业出版社,2004.
    [9]许谋奎,马人乐.镇江电厂烟气脱硫吸收塔有限元计算分析[J].特种结构,2005,22(2):23-25.
    [10]任涛,陈务军,张丽梅,等.可门电厂烟气脱硫吸收塔结构计算分析[J].工业建筑,2006(S1):557-561.
    [11]叶献国,钟维军,赵书锋.脱硫塔结构得有限元分析及动力简化计算[J].钢结构,2007(10):42-46.
    [12]盛宏玉.结构动力学[M].合肥:合肥工业大学出版社,2005.
    [13]胡聿贤.地震工程学[M].北京:地震出版社,2006.
    [14]GB50011—2001,建筑抗震设计规范[S].
    [15]李爱群,高振世.工程结构抗震设计[M].北京:中国建筑工业出版社,2005.
    [16]刘晶波,杜修力.结构动力学[M].北京:机械工业出版社,2005.
    [17]丰定国,王社良.抗震结构设计[M].武汉:武汉理工大学出版社,2003.
    [18]陈国兴,陈忠汉,马克俭,等.工程结构抗震设计原理[M].北京:中国水利水电出版社,2002.