含填充墙钢管混凝土框架抗震性能
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
为了解决含填充墙钢管混凝土框架结构的抗震性能,通过对两榀单跨两层带填充墙矩形钢管混凝土框架进行水平低周反复加载试验,深入研究了此种结构的承载能力、延性、耗能能力以及破坏机制;研究结果表明:带填充墙矩形钢管混凝土框架结构滞回曲线饱满,耗能能力强,有较稳定的后期承载力,具有良好的抗震性能。此种结构有进一步研究和在实践中推广应用的价值。
To understand the seismic behavior of concrete filled steel tubular frame of infill wall,an experimental loading test on two pieces,single span and double stories RHS frame of infill wall was conducted to investigate its bearing capacity,ductility,energy dissipation and collapse mechanism. The results show that RHS frame has plumper shuttle shape hysteretic curves,excellent energy dissipation,and stable loading capacity. Therefore the frame has superiority over seismic behavior.
引文
[1]陈倩.方钢管混凝土框架抗震性能试验研究[D].天津大学土木学院,2003.
    [2]JGJ101-96.建筑抗震试验方法规程[S].北京:中国建筑工业出版社,1997.
    [3]孙修礼.钢管混凝土框架骨架曲线研究[J].地震杆长与工程振动,2007,27(1):99-104.
    [4]李斌.钢管混凝土框架结构抗震性能试验研究[J].包头钢铁学院学报,2002,21(2):174-178.
    [5]张慧,卢会芳,填充墙对框架结构体系侧移刚度的影响[J].河南大学土木建筑学报,1993,47(5):79-80.
    [6]赵庆.方钢管混凝土框架抗震性能试验研究[D].天津大学土木学院,2003.
    [7]关国雄,夏敬谦,钢筋混凝土框架砖填充墙结构抗震性能的研究[J].地震工程与工程振动1996,4(14)85-91.
    [8]邹昀.带砌体填充墙的钢筋混凝土框架受力性能分析[J].江南大学学报,2002,1(1):76-81.
    [9]张雅君.填充墙对钢筋混凝土框架结构受力及变形性能的改善[J].工程建设与设计,2001,6:37-39.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心