We extended the Britter and McQuaid approach (1988) for estimating dense gas plume length to multiple leakage sources.
The proposed method is conservative, but can run very fast to be used in Monte Carlo simulations.
The method is implemented in GCS risk assessment including uncertainty quantification within the framework of NRAP-IAM.