Modified incremental conductance MPPT algorithm to mitigate inaccurate responses under fast-changing solar irradiation level
详细信息    查看全文
文摘
During the increment of solar irradiation, the conventional incremental conductance algorithm responds inaccurately at the first step change in the converter duty cycle. This paper presents the conventional algorithm confusion and proposes a modified incremental conductance algorithm that responds accurately when the solar irradiation level increases. Moreover, the proposed algorithm shows zero oscillation in the power of the solar module after the maximum power point (MPP) is tracked. MATLAB simulation is carried out with the modified incremental conductance algorithm under a fast-changing solar irradiation level. Results of the modified, conventional and variable step size incremental conductance algorithms are compared. Finally, the hardware implementation, consisting of a single-ended primary-inductor converter (SEPIC) and a PIC controller, is applied as the maximum power point tracking (MPPT) controller. The simulation and experimental works showed that the proposed algorithm performs accurately and faster during the increment of solar irradiation level.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700