An axial vibration membrane (AVM) was designed to control membrane fouling.
Enhancing shear rate can improve critical flux and reduce membrane fouling.
XDLVO theory explained why membrane was more easily fouled at low shear rate.
Interaction force expounded how AVM controlled algae adhering to membrane.
The mechanism of AVM controlling membrane fouling was presented.