Hepatic CT perfusion measurements: A feasibility study for radiation dose reduction using new image reconstruction method
详细信息    查看全文
文摘

Objectives

To assess the effects of image reconstruction method on hepatic CT perfusion (CTP) values using two CT protocols with different radiation doses.

Materials and methods

Sixty patients underwent hepatic CTP and were randomly divided into two groups. Tube currents of 210 or 250 mA were used for the standard dose group and 120 or 140 mA for the low dose group. The higher currents were selected for large patients. Demographic features of the groups were compared. CT images were reconstructed by using filtered back projection (FBP), image filter (quantum de-noising, QDS), and adaptive iterative dose reduction (AIDR). Hepatic arterial and portal perfusion (HAP and HPP, ml/min/100 ml) and arterial perfusion fraction (APF, % ) were calculated using the dual-input maximum slope method. ROIs were placed on each hepatic segment. Perfusion and Hounsfield unit (HU) values, and image noises (standard deviations of HU value, SD) were measured and compared between the groups and among the methods.

Results

There were no significant differences in the demographic features of the groups, nor were there any significant differences in mean perfusion and HU values for either the groups or the image reconstruction methods. Mean SDs of each of the image reconstruction methods were significantly lower (p < 0.0001) for the standard dose group than the low dose group, while mean SDs for AIDR were significantly lower than those for FBP for both groups (p = 0.0006 and 0.013). Radiation dose reductions were approximately 45 % .

Conclusions

Image reconstruction method did not affect hepatic perfusion values calculated by dual-input maximum slope method with or without radiation dose reductions. AIDR significantly reduced images noises.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700