建立了区分岩土和回填区的地埋管换热器分区数值分析模型。采用数值分析手段分析了回填材料导热系数在不同地埋管间距、不同管径和不同埋管类型中的影响规律,对回填材料在地源热泵系统中的实际工程应用具有指导意义。
This paper establishes a numerical analysis model for the geothermal heat exchanger partition of geotechnical and backfilling areas.The influence of thermal conductivity of backfill materials on different pipe spacings, different pipe diameters and different buried pipe types was analyzed by numerical analysis. This has guiding significance for the practical engineering application of backfill materials in ground source heat pump system.
引文
[1]张旭,高晓兵.华东地区土壤及土沙混合物导热系数的实验研究[J].暖通空调,2004,34(5):83-85.
[2]刁乃仁,方肇洪.地埋管地源热泵技术[M].北京:高等教育出版社,2006.
[3]SannerB,Mands E,SauerMK.Larger geothermal heat pump plants in the central region of Germany[J].Geothermics,2003,32(4-6):589-602.
[4]Kavanaugh S P,Allan M L.Testing of thermally enhanced cement ground heat exchanger grouts[J].1999.
[5]Lenarduzzi F J,Cragg C B H,Radhakrishna H S.The importance of grouting to enhance the performance of earth energy systems[J].2000.
[6]庄迎春,孙友宏,谢康和.直埋闭式地源热泵回填料性能研究[J].太阳能学报,2004,25(2):216-220.
[7]范军,胡玉秋,孙奉仲,等.竖直双U型埋管地热换热器支管间热短路分析[J].可再生能源,2011,29(4):95-97.
[8]包强,邓启红,牛润卓.回填材料对土壤热泵U型埋管换热器性能的影响[J].建筑热能通风空调,2007,26(4):64-67.