摘要
本文简单分析了为何要测定醌茜含量,并根据SN/T1788-2006《醌茜的测定萃取分光光度法》对分光光度法测定醌茜含量的不确定度进行了建模,最后依据JJF1059-2012《测量不确定度评定与表示》和CNAS-GL06:2006《化学分析中不确定度的评估指南》分析了各个不确定度分量来源,对各分量逐一进行评定及汇总。
This paper briefly analyzes why the content of strontium is determined, and the uncertainty of the determination of strontium content by spectrophotometry is modeled according to SN/T1788-2006 ""Determination of quinizarin-Extraction spectrophotometric method"". Finally, according to JJF 1059-The 2012 Measurement Uncertainty Evaluation and Representation and CNAS-GL06:2006 "Guidelines for the Evaluation of Uncertainty in Chemical Analysis" analyze the sources of each uncertainty component and evaluate and summarize each component one by one.
引文
[1]SN/T1788-2006《醌茜的测定萃取分光光度法》[S].
[2]JJF 1059-2012《测量不确定度评定与表示》[S].
[3]CNAS-GL06:2006《化学分析中不确定度的评估指南》[S].