摘要
针对某埋置于可液化土层中的盾构法综合管廊工程,该文介绍了采取压密注浆的抗液化沉陷和抗上浮措施,并进行了地震液化时的抗浮验算和压密注浆方案设计。该方案设计可供相关工程参考。
Aiming at an engineering tunnel project embedded in liquefiable soil by shield process,the article introduces the use of the compact grouting of anti-liquefiable sinking and anti-floating measures,and designs the anti-floating checking computation and the compact grouting scheme of the earthquake liquefaction.This scheme design can be referred for the similar projects.
引文
[1]朱百里,沈珠江.计算土力学[M].上海:上海科学技术出版社,1990:14-25.
    [2]蔡建厚、刘学杰、侯忠良,等.地下管线抗震[J].计算方法与工程应用,1991(,11):147-57.
    [3]Newmark N M,Hall W J.Pipeline design to resist large faultdisplacement[A].Proceedings of First US Conference on EarthquakeEngineering[C],AnnArbor,1975:416-425.
    [4]林均岐.熊建国液化场地土中埋设管线的上浮反应分析[J].地震工程与工程振动,2000,20(2):97-100.
    [5]GB 50011-2010,建筑抗震设计规范[S].
    [6]GB50191-93,构筑物抗震设计规范[S].
    [7]JTG/T D70-2010,公路隧道设计细则[S].
    [8]GB50007-2002,建筑地基基础设计规范[S].