插入式混合坝接头部位有限元静动力分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
针对混合坝接头部位地震分析比较少,笔者选择了插入式混合坝进行研究,在混凝土刺墙与粘土心墙两种材料接触面上用极薄层单元来模拟,选用沈珠江弹塑性模型和等价非线性粘弹性模型。通过对混合坝进行有限元静力和地震计算,详细分析了混合坝连接处各个接触面上的静动力反应,并给出了插入式混合坝接头部位抗震措施。
Nowadays, there is little seismic analysis of the connection of mixed dam, hence the inserted type mixed dam is selected as the subject of this research. Paper elements are used to simulate the contact surface between concrete key wall and clay core, and Shen Zhu-jiang model and equivalent non-linear viscoelastic model are adopted. By FEM static and dynamic calculation, the static and dynamic response on every contact surface is analyzed, based on which the anti-earthquake measures are put forward in this article.
引文
[1] 吕凯歌.混凝土面板堆石坝三维有限元动力反应分析[D].大连:大连理工大学,1999.
    [2] 郭诚谦,陈慧远.土石坝[M].北京:水利电力出版社,1981.
    [3] 殷宗泽,等.土与结构材料接触面的变形及其数学模拟[J].岩土工程学报,1994,16(3):14-22.
    [4] 钱家欢,殷宗泽.土工原理与计算[M].北京:水利电力出版社,1994.
    [5] 顾淦臣.土石坝地震工程[M].南京:河海大学出版社,1989.
    [6] 刘松涛,于丙子.丹江口水利枢纽左联混凝土坝与土石坝连接坝段三维动力反应分析[A].土石坝工程交流论文集[C].1993(3/4):203-211.
    [7] 大连理工大学土木系.面板堆石坝永久变形、面板应力及抗震措施研究,"八五"国家科技攻关(85-208-02-04-02-08)报告[R].大连:大连理工大学,1995.