某别墅首层柱顶隔震设计分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对某别墅进行首层柱顶隔震设计。时程分析表明:在7度多遇地震作用下,隔震结构与非隔震结构相比,隔震层以上最大层间剪力比为0.26,减震效果明显;首层柱子按7度罕遇地震作用下产生的内力进行强度设计,具有足够的强度;分析对比了隔震结构和非隔震结构在7度和8度罕遇地震下的层间位移角,结果表明隔震结构在罕遇地震下的层间位移角远远小于非隔震结构,隔震结构在大震下表现出了良好的工作性能。
Design of isolation on the top of columns for a villa was taken.Time history analysis showed that: story shear force of isolation structure was reduced compared to non-isolation structure under the multi frequency of 7 degree.Columns of first floor were designed under the rare frequency of 7 degree and have enough strength.Inter-story displacement angle of isolation structure and non-isolation structure was analyzed and compared showing that inter-story displacement angle of isolation structure was far lower than inter-story displacement angle of non-isolation structure under rare earthquake.Isolation structure worked well under the rare earthquake.
引文
[1]祁皑.层间隔震技术评述[J].地震工程与工程振动,2004,24(6):114-120.
    [2]潘鹏,曹海韵,齐玉军,等.底部薄弱层结构的柱顶隔震加固改造设计[J].工程抗震与加固改造,2000,20(3):100-107.
    [3]吴应雄,祁皑.柱顶隔震技术在首层薄弱层框架结构中的应用[J].延边大学学报(自然科学版),2011,39(6):860-865.
    [4]GB50011-2010,建筑抗震设计规范[S].
    [5]吴应雄,祁皑,颜学渊.首层薄弱层框架结构的柱顶隔震性能分析[J].南昌大学学报(工科版),2011,33(4):936-940.