复合隔震结构模型振动台试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
作者对一个二层复合隔震结构钢框架模型进行了振动台试验,该模型采用夹层橡胶支座与摩擦滑移支座并联组合作为隔震层,既能提供足够的弹性恢复力,又具有良好的结构耗能能力。试验测得结构各项动力响应,并将软件计算数据与试验数据进行了比较,结果表明复合隔震结构的加速度反应小,楼层层间位移也较小,上部结构基本为平动,结构耗能能力显著,而且软件可以很好地模拟结构的地震反应规律。
A two-floor steel-frame model of composite isolation structure is tested to simulate the earthquake action on shaking table.The isolator layer of model is combined by laminated rubber bearings and sliding isolation bearings.It can provide sufficient elastic resilience and consume earthquake energy effectually.Structure dynamic response in the test was compared with that of analysing in the software.It is shown that frame acceleration response and relative storey displacement are both small in composite isolation structure,which can consume large earthquake energy.then it can be reflected by the software analysing.
引文
[1]周福霖.工程结构减震控制[M].北京:科学出版社,1997.
    [2]冼巧玲,周福霖,王伟.橡胶垫隔震框架结构试验研究[J].世界地震工程,1996,(4):23-27.
    [3]杨树标,杨艳秋,高天宝,等.框架复合隔震结构地震响应分析[J].河北建筑科技学院学报,2006,23(1):23-26.
    [4]朱玉华,吕西林,施卫星.基础隔震房屋模型振动台试验研究[J].地震工程与工程振动,2000,20(3):123-129.