回转式空气预热器改造技术的探讨
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
为解决电厂锅炉空气预热器漏风率过高的问题,提出了新的空气预热器改造方案,其技术关键是通过安装新的扇形板和轴向密封板,形成双密封;在转子轴的密封中增加迷宫密封等方法,使漏风率由30%下降到9%,保证了锅炉正常运行及运行的经济性。
Air preheater's high leakage is the main factor which affect boiler running safety and running economically. In the airpreheater retrofit of Jiangjin thermal power station, installed new-design sectorplate and axial sectorplate, became double sealing construction; Add labyrinthine sealing to main shaft, and so on, then the leakage of airpreheater was fall to 9% from 30%. The retrofit approaches were recited and the know-how of retrofit was discussed in this article.
引文
[1] 黄其励等.电站锅炉空气预热器[M].北京:中国电力出版社,2002
    [2] 范从振主编.锅炉原理[M].北京:北京水利电力出版社,1986
    [3] 童其武、张孝勇主编.锅炉安装调试运行维护实用手册[M].北京:地震出版社,1999