招商银行上海大厦连桥部分弹塑性时程分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
结合现行国家规范与规程,采用弹塑性时程分析方法,对招商银行上海大厦连桥部分这一连体结构进行抗震分析,探讨连体结构在罕遇地震作用下的动力响应。对剪力墙进行等效化处理,重点讨论了在罕遇地震作用下结构的基底剪力及剪重比、层间位移角以及结构整体塑性发展的过程。计算结果显示,与连廊桁架相连的部分墙体和筒体根部的墙体为结构的薄弱部位,塑性发展程度大,设计时应引起重视。结构最大层间位移角为1/192,满足规范相关要求。
Combined with present national codes and regulations,elasto-plastic time history analysis with connected bridge of China merchants bank tower shanghai building was carried out.The dynamic response of this connected structure under rare earthquake had been discussed.With the equivalence shear wall,the base shear force and shear-weight ratio as well as the inter-story drift and plastic development process of the whole structure had been studied.The analysis results show that,the wall which connect with gallery and on the bottom of tube shell wall are easily to be destroyed.It is necessary to pay attention to this phenomenon.The maximum inter-story drift of the structure is 1/192,it is in good requirement with the code for seismic.
引文
[1]隗萍,吴明军,蒋志强,等.成都某大厦大底盘双塔连体结构抗震设计[J].四川建筑科学研究,2007,33(4):154-158.
    [2]JGJ 3-2002.高层建筑混凝土结构技术规程[S].JGJ3-2002.
    [3]GB 50011-2001.建筑抗震设计规范[S].
    [4]陈文兵,唐家祥.水平任意向地震输入下双塔楼连体结构的动力分析[J].振动与冲击,2003,22(1):29:33.
    [5]尹超,周颖,吕西林.上海国际设计中心超限高层结构抗震设计[J].结构工程师,2008,24(6):80-84.
    [6]黄坤耀,孙炳楠,楼文娟.连体刚度对双塔连体高层建筑地震响应的影响[J].建筑结构学报,2001,22(3):21-26.
    [7]刘晶波,李征宇,石萌,等.大跨高层连接体建筑结构动力分析[J].建筑结构学报,2004,25(1):45-52.
    [8]招商银行上海大厦项目初步设计报告书[R].2007.
    [9]北京金土木软件技术有限公司.Sap 2000中文版使用指南[M].人民交通出版社,2008.
    [10]程绍革,王理,张允顺.弹塑性时程分析方法及其应用[J].建筑结构学报,2000,21(1):52-56.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心