摘要
厦门翔安新圩卫生院的医技综合楼工程结构采用一层柱顶隔震设计。本文从工程隔震设计专项技术论证意见、橡胶支座规格及其力学性能选择、隔震结构的动态特性测试要求、隔震房屋的施工、质量监督、和维护等方面进行了分析与讨论,提出了工程在施工中应注意的各类问题。本文可供同类隔震工程借鉴。
Xiamen Xinxu Xiangan hospitals medical technology complex engineering structures using a layer of vibration isolation design capitals.In this paper,isolated from the engineering design of the views of special technical demonstration,rubber bearings and mechanical properties of standard options,the dynamic characteristics of isolated structures testing requirements,isolation housing construction,quality supervision,and maintenance are analyzed and discussed,the During the construction of the project should pay attention to various problems.In this paper,isolation of similar projects for reference.
引文
[1]日本免震构造协会.隔震结构入门[M].叶列平译.科学出版社,1998.
    [2]周福霖.工程结构隔震减震研究进展[M].北京:地震出版社,2004.
    [3]祁皑.层间隔震技术评述[J].地震工程与工程振动,2004,24(6):114~120.
    [4]郑国琛.参考参数优化的层间隔震结构振动台试验研究[D].福州大学,2007.1.
    [5]中华人民共和国建设部主编.建筑抗震设计规范(20011-2001)[S].北京:中国建筑工业出版社,2001.
    [6]中国工程建设标准化协会.CECS126:200.叠层橡胶支座隔震技术规程[S].2001.