十三陵抽水蓄能电站地下厂房结构动力分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
以十三陵抽水蓄能电站地下厂房为原型,对其不同的结构形式作了动力分析研究,指出这类厂房结构的减振设计的有效措施是加强楼板的约束和提高楼板的法向刚度;由于机墩刚度较大,因此机墩局部削弱的不同拆卸方案对整个结构的动力特性影响不大;而中拆方案对机墩的刚度削弱最大,对减振设计最为不利.
Dynamical property and response of the underground powerhouse of Shisanling Pumped Storage Power Station is studied for its different structural patterns.The results indicate that the best way to reduce the vibration of the powerhouse is to reinforce its restriction of the floor and enhance its normal rigidity.The partial weakening of the generator frustum have no much effect on the dynamical property for its large rigidity;on the contrary,the way to disassemble from the middle will be the most disadvantageous for the earthquake control.
引文
[1]董毓新,李彦硕.水电站建筑物结构分析[M].大连:大连理工大学出版社,1995.
    [2]董毓新.水轮发电机组振动[M].大连:大连理工大学出版社,1989.
    [3]朱以文,徐晗,蔡元奇.交界面非协调网格连结的新约束方程法[J].武汉大学学报(工学版),2003,38(6):47-50.
    [4]杜晓京.地下厂房机组支撑结构振动观测与分析[J].水力发电,1999(2):27-30.
    [5]蔡元奇,段克让,朱以文.诊断弧形闸门振动状态的方法研究[J].武汉水利电力大学学报,1999,32(3):47-50.
    [6]王俊红,黄勇.广蓄二期工程地下厂房结构振动研究及减振措施[J].水力发电,2001(11):30-34.
    [7]蔡元奇,韩芳,朱以文.场地卓越周期与结构基本周期关系研究[J].地震工程与工程振动,2004(4):70-75.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心