某钢筋混凝土框架厂房的抗震鉴定
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
基于Pushover分析的抗震评估方法,提出了使用层间位移角以及结构在大震下的塑性铰转角来评估钢筋混凝土框架结构的抗震性能,给出了新的抗震性能评估步骤。使用所推荐的方法对一钢筋混凝土框架厂房进行了抗震性能评估,并且与实际震害记录对比,结论一致。结果表明,该方法从结构整体性能分析出发,可以快速有效地评估结构的抗震性能,该方法也可以为结构加固后的抗震评估奠定基础。
A new method of seismic evaluation for reinforced concrete frame structure based on Pushover analysis is introduced.Story drift and plastic hinge comer are used to evaluate reinforced concrete structure.From the applied illustration,it can clearly be seen that this method can quickly and scientifically evaluate reinforced concrete frame structure as structure is overall analyzed,at the same time,conclusions are similar to earthquake damage records. Reinforced frame can be evaluated by this method.
引文
[1] 魏琏.高层及多层钢筋混凝土建筑抗震设计手册[M].北京:地震出版社,1990.
    [2] 李培林.建筑抗震与结构选型构造[M].北京:中国建筑工业出版社,1990.
    [3] 吕西林,王亚勇,郭子雄.建筑结构抗震变形验算[J].建筑科学,2002,18(1) .
    [4] 高小旺,钟益村,陈德彬.钢筋混凝土框架房屋震害预测方法[J].建筑科学,1989,(1) .
    [5] 建筑抗震鉴定标准(GB50023-95) [S].北京:中国建筑工业出版社,1995.
    [6] 李国胜.建筑结构裂缝及加层加固疑难问题的处理-附实例[M].北京:中国建筑工业出版社,2006.
    [7] 中国建筑科学研究院.钢筋混凝土框架结构抗震鉴定和加固方法研究[M].北京:建筑科学研究报告,1988.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心