引文
[1]徐培福,戴国莹.超限高层建筑结构基于性能抗震设计的研究[J].土木工程学报,2005,38(1):1―10.Xu Peifu,Dai Guoying.Performance-based seismic design of tall building structures beyond the code-specification[J].China Civil Engineering Journal,2005,38(1):1―10.(in Chinese)
[2]Wu Y F,Liu T,Oehlers D J.Fundamental principles that govern retrofitting of reinforced concrete columns by steel and FRP jacketing[J].Advances in Structural Engineering,2006,9(4):507―533.
[3]Priestley M J N,Seible F,Calvi M.Seismic design and retrofit of bridges[M].New York:Wiley,1996:686.
[4]Paultre P,Légeron F.Confinement reinforcement design for reinforced concrete columns[J].Journal of Structural Engineering ASCE,2008,134(5):738―749.
[5]李静,钱稼茹.碳纤维布约束混凝土柱的非线性分析[J].工程力学,2005,22(1):159―163.Li Jing,Qian Jiaru.Nonlinear analysis of carbon fiber sheet confined concrete columns[J].Engineering Mechanics,2005,22(1):159―163.(in Chinese)
[6]Sause R,Harries K A,Walkup S L.Flexural behaviour of concrete columns retrofitted with carbon fiber-reinforced polymer jackets[J].ACI Structural Journal,2004,101(5):708―716.
[7]魏洋,吴刚,吴智深,等.FRP约束混凝土矩形短柱的延性分析[J].地震工程与工程振动,2009,29(3):71―76.Wei Yang,Wu Gang,Wu Zhishen,et al.Ductility analysis of FRP-confined short rectangular reinforced concrete columns[J].Journal of Earthquake Engineering and Engineering Vibration,2009,29(3):71―76.(in Chinese)
[8]熊朝晖,潘德恩.钢筋混凝土框架柱侧向变形能力的研究[J].地震工程与工程振动,2001,21(2):103―108.Xiong Zhaohui,Pan Deen.Study on lateral deformability of reinforced concrete frame columns[J].Earthquake Engineering and Engineering Vibration,2001,21(2):103―108.(in Chinese)
[9]张柯,岳清瑞,叶列平.碳纤维布加固混凝土柱滞回耗能分析及目标延性系数的确定[J].工业建筑,2001,31(6):5―8.Zhang Ke,Yue Qingrui,Ye Lieping.Analysis ofhysteresis energy dissipation and acceptable ductility factor for concrete column strengthened with CFS[J].Industrial Construction,2001,31(6):5―8.(in Chinese)
[10]谢剑,刘明学,赵彤.碳纤维布提高高强混凝土柱抗震能力评估方法[J].天津大学学报,2005,38(2):109―113.Xie Jian,Liu Mingxue,Zhao Tong.Anti-seismic performance evaluating method of high strength concrete columns retrofitted with CFRP fabric[J].Journal of Tianjin University,2005,38(2):109―113.(in Chinese)
[11]顾冬生,吴刚,吴智深,等.CFRP加固高轴压比钢筋混凝土短圆柱抗震性能试验研究[J].工程抗震与加固改造,2006,28(6):71―77.Gu Dongsheng,Wu Gang,Wu Zhishen,et al.Experimental study on seismic performance of RC short circular columns strengthened with CFRP composites under high level compression[J].Earthquake Resistant Engineering and Retrofitting,2006,28(6):71―77.(in Chinese)
[12]王震宇,芦学磊,李伟,等.塑性铰区碳纤维约束高强混凝土圆柱抗震性能的试验研究[J].建筑结构,2009,39(2):21―24.Wang Zhenyu,Lu Xuelei,Li Wei,et al.Experimental research on seismic performance of high strength concrete circular column confined with carbon fiber sheets at plastic hinge zone[J].Building Structure,2009,39(2):21―24.(in Chinese)
[13]Gu Dongsheng,Wu Gang,Wu Zhishen,et al.The confinement effectiveness of FRP in retrofitting circular concrete columns under simulated seismic load[J].Journal of Composites for Construction ASCE,2010,14(5):531―540.
[14]Binici B.Design of FRPs in circular bridge column retrofits for ductility enhancement[J].Engineering Structures,2008,30:766―776.
[15]Sheikh S A,Yau G.Seismic behavior of concrete columns confined with steel and fiber-reinforced polymers[J].ACI Structural Journal,2002,99(1):72―81.
[16]Lehman D E,Moehle J P.Seismic performance of well-confined concrete bridge columns[R].Berkeley:Pacific Earthquake Engineering Research Center,2000:316.
[17]Paultre P,Eid R,Robles H I,et al.Seismic performance of circular high-strength concrete columns[J].ACI Structural Journal,2009,106(4):395―404.
[18]Watson S,Park R.Simulated seismic load tests on reinforced concrete columns[J].Journal of Structural Engineering ASCE,1994,120(6):1825―1849.
[19]Berry M P,Eberhard M O.Practical performance model for bar buckling[J].Journal of Structural Engineering ASCE,2005,131(7):1060―1070.
[20]Lam L,Teng J G.Design-oriented stress-strain model for FRP-confined concrete[J].Construction and Building Materials,2003,17:471―489.
[21]Gu Dongsheng,Wu Gang,Wu Zhishen.Ultimate flexural strength of normal section of FRP confined RC circular columns[J].Journal of Southeast University(English Edition),2010,26(1):107―111.
[22]Ozbakkaloglu T,Saatcioglu M.Seismic behavior of high-strength concrete columns confined by fiber-reinforced polymer tubes[J].Journal of Composites for Construction ASCE,2006,10(6):538―549.
[23]Chai Y H,Priestley M J N,Seible F.Seismic retrofit of circular bridge columns for enhanced flexural performance[J].ACI Structural Journal,1991,88(5):572―584.
[24]Xiao Y,Wu H,Martin G R.Prefabricated composite jacketing of RC columns for enhanced shear strength[J].Journal of Structural Engineering ASCE,1999,125(3):255―264.
[25]Li Y F,Sung Y Y.A study on the shear-failure of circular sectioned bridge column retrofitted by using CFRP jacketing[J].Journal of Reinforced Plastics and Composites,2004,23(8):811―830.
[26]Sheikh S A,Li Y M.Design of FRP confinement for square concrete columns[J].Engineering Structures,2007,29:1074―1083.
[27]张国军,吕西林,刘伯权.轴压比超限时框架柱的恢复力模型研究[J].建筑结构学报,2006,27(1):90―98.Zhang Guojun,LüXilin,Liu Boquan.Research on restoring force models of frame columns with ultra-limited axial compression ratio[J].Journal of Building Structures,2006,27(1):90―98.(in Chinese)