变刚度滞变耗能与隔震联合控制框架结构实验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对原有变刚度滞变-摩擦隔震支座进行了改进,提出一种多级变刚度滞变耗能器,并进行了初步的试验研究。在此基础上,对一纯框架结构(1:5)模型进行了耗能与隔震的联合控制试验研究,试验结果表明,采用这种联合控制技术能降低不同大小地震下的结构反应,具有很强的适应性。
In this paper, the stiffnesvariable hystereticfriction isolation support is improved, and a kind of energydissipation device with multilevel variablestiffness is presented. At the same time, the preliminary test research for the energy dissipation device is conducted. On these bases, energydissipation and earthquakeisolation test investingations is carrie out with a 1/5 framework structure model without wall. The results of the test show that it is able to reduce the responses of the structure under different intensities and has a great adaptation for the control ling seismic response of the structure.
引文
[1] 王伟,王焕定,等.钢管混凝土短柱支座隔震性能研究[J].工程力学,1997,3(增刊):113-117.
    [2] 孙峰,张永山,等.变刚度钢管混凝土短柱隔震装置的性能研究[J].地震工程与工程振动,1999,19(3):127-130.
    [3] 王伟,王焕定,等.钢管混凝土支座隔震房屋试验研究[J].振动工程学报,1999,12(2):292-296.
    [4] 张永山,等.变刚度钢管混凝土短柱隔震装置的试验分析与研究[J].世界地震工程,2000,16(2):23-27.
    [5] 王焕定,付伟庆,等.多级变刚度滞变耗能的设计思想和可行性实验研究[J].地震工程与工程振动,2001,21(4):154-158.
    [6] 张建国.滞变-摩擦基底隔震系统研究[D].哈尔滨:哈尔滨建筑大学,2000.
    [7] 赵桂峰.变刚度被动控制系统的研究[D].哈尔滨:哈尔滨工业大学,2001.