引文
[1]周福霖.工程结构减震控制[M].北京:地震出版社,1997.
[2]姚谦峰,丰定国,王清敏.滚动隔震结构受力分析[J].西安建筑科技大学学报,1999,31(3):249-252.YAO Qian-feng,FENG Ding-guo,WANG Qing-min.Mechanical analysis of rolling ball isolation system[J].Journal of Xi'an University of Architecture&Technology,1999,31(3):249-252.
[3]江宜城,唐家祥.单层框架建筑模型基础隔震实验研究[J].世界地震工程,1999,15(3):74-78.JIANG Yi-cheng,TANG Jia-xiang.Experimental study on abase-isolated building model[J].World EarthquakeEngineering,1999,15(3):74-78.
[4]朱玉华,吕西林,施卫星.基础隔震房屋模型振动台试验研究[J].地震工程与工程振动,2000,20(3):123-129.ZHU Yu-hua,LXi-lin,SHI Wei-xing.Research onshaking table test of base isolation building[J].EarthquakeEngineering and Engineering Vibration,2000,20(3):123-129.
[5]吕西林,朱玉华,施卫星.组合基础隔震房屋模型振动台试验研究[J].土木工程学报,2001,34(2):43-49.lXi-lin,ZHU Yu-hua,SHI Wei-xing.Shaking table test onbuilding models with combined isolation system[J].Chinacivil Engineering Journal,2001,34(2):43-49.
[6]张文芳,李爱群,税国斌.九层房屋基础滑移隔震的试验、分析及应用研究[J].建筑结构学报,2000,12(3):60-68.ZHANG Wen-fang,LI Ai-qun,SHUI Guo-bin.Experiments,theoretical analyses and applied research on base slidingisolation of multi-story buildings[J].Journal of BuildingStructures,2000,12(3):60-68.
[7]黄襄云,周福霖,金建敏.多层隔震与非隔震框剪结构振动台对比试验研究[J].建筑结构,2007,37(8):55-58.HUANG Xiang-yun,ZHOU Fu-lin,JIN Jian-min.Simulatedshaking table test research of Isolated and non-isolatedframe-shear wall structure mode[J].Building Structures,2007,37(8):55-58.
[8]杨林,常永平,周锡元.FPS隔震体系振动台试验与有限元模型对比分析[J].建筑结构学报,2008,29(4):66-72.YANG Lin,CHANG Yong-ping,ZHOU Xi-yuan.Contrastiveanalysis of shaking table test and finite element model onfriction pendulum isolated system[J].Journal of BuildingStructures,2008,29(4):66-72.
[9]杨林,周锡元,苏幼坡.FPS摩擦摆隔震体系振动台试验研究与理论分析[J].特种结构,2005,22(4):43-46.YANG Lin,ZHOU Xi-yuan,SU You-po.Shaking table testresearch and theoretical analysis on friction pendulum isolatedsystem[J].Special Structures,2005,22(4):43-46.
[10]霍林生,李宏男,刘猛.调液阻尼器对偏心结构扭转耦联振动控制的试验研究[J].振动与冲击,2011,30(11):198-202.HUO Lin-sheng,LI Hong-nan,LIU Meng.Experimentalstudy on torsionally coupled structural vibration control ofeccentric buildings using tuned liquid dampers[J].Journal ofVibration and Shock,2011,30(11):198-202.
[11]王鑫.钢筋混凝土模型框架振动台试验分析和抗震性能评估[D].西安:西安建筑科技大学,2006.
[12]张敏政.地震模拟试验中相似律应用的若干问题[J].地震工程与工程振动,1997,17(2):52-58.ZHANG Min-zheng.Study on similitude laws for shakingtable tests[J].Earthquake Engineering and EngineeringVibration,1997,17(2):52-58.
[13]周颖,卢文胜,吕西林.模拟地震振动台模型实用设计方法[J].结构工程师,2003,(3):30-38.ZHOU Ying,LU Wen-sheng,lXi-lin.Practical modeldesign method of shaking table tests[J].StructuralEngineers,2003,(3):30-38.
[14]周颖,吕西林,卢文胜.不同结构的振动台试验模型等效设计方法[J].结构工程师,2006,22(4):37-40.ZHOU Ying,lXi-lin,LU Wen-sheng.Shaking table testmodel design in different structures[J].StructuralEngineers,2006,22(4):37-40.
[15]齐娟.满配置与欠配重模型振动台试验技术研究[D].北京:中国建筑科学研究院,2009.
[16]杨旭东.振动台模型试验若干问题的研究[D].北京:中国建筑科学研究院,2005.
[17]混凝土结构设计规范(GB50011—2002)[S].北京:中国建筑工业出版社,2002.
[18]吕西林,施卫星.高层建筑结构模型试验中的若干问题探讨[J].《第14届全国高层建筑结构学术交流会论文集》,1996.LV Xi-lin,SHI Wei-xing.Issues discussion of high-risebuildings in the structural model test[J].The 14th nationalHigh-rise Building Structure Proceedings of AcademicExchange,1996.
[19]李德寅,王邦楣,林亚超.结构模型试验[M].北京:科学出版社,1996.
[20]张敏政,孟庆利,刘晓明.建筑结构的地震模拟试验研究[J].工程抗震,2003,12(4):31-35.ZHANG Min-zheng,MENG Qing-li,LIU Xiao-ming.Buildingstructure’s earthquake simulation experimental research[J].Engineering Anti-seismic,2003,12(4):31-35.