防屈曲钢支撑加固某食堂结构的弹塑性时程分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
采用弹塑性时程分析方法,对北京某大空间食堂结构进行了抗震性能评估,研究了采用消能防屈曲钢支撑加固后结构的抗震性能。分析结果表明,增设防屈曲钢支撑可显著降低框架结构的最大层间位移,控制结构的塑性损伤,提高结构的抗震性能。本文方法可供类似工程参考。
In this paper,the seismic performance of a certain dining-room in Beijing with spacious framework is evaluated by elastic-plastic time history analysis,and the effect on seismic performance of the building is studied by fixing buckling restrained steel braces in the framework.The analysis result indicates that retrofitting framework structure with buckling restrained steel braces can observably reduce the displacement response,control the damage of the structure and improve the seismic performance of the building.
引文
[1]邓长根,何永超.日本建筑结构隔震减震研究新进展[J].世界地震工程,2002,18(3)Deng Chang-gen,He Yong-chao.New Advances inEarthquake Isolation and Vibration Reduction of BuildingStructures in Japan[J].World Information onEarthquake Engineering,2002,18(3)(in Chinese)
    [2]Unbonded Brace:From Research to Californian Practice.(http://www.arup.com/DOWNLOADBANK/download172.pdf)
    [3]孙艳文.钢骨消能支撑钢框架抗震性能研究[D].西安:西安建筑科技大学,2005Sun Yan-wen.Study on Seismic Behavior of BucklingRestrained Braced Frame[D].Xi'an:Xi'an University ofArchitecture and Technology,2005(in Chinese)
    [4]邓继明,将建群.基于弹塑性动力分析的结构非线性响应及抗震设计[J].工业建筑,2004,34(10):31~33Deng Ji-ming,Jiang Jian-qun.Nonlinear Response andSeismic Design of Structures Based on ElastoplasticDynamic Analysis[J].Industrial Construction,2004,34(10):31~33(in Chinese)

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心