超高层主楼与裙房黏滞阻尼器连接减振分析研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
针对上海世茂国际广场裙房(广场)部分由于刚度与质量分布之间的偏心导致扭转变形突出这一问题,采用CANNY程序对主楼和裙房之间黏滞阻尼器连接减振方法开展一系列非线性时程分析,从裙房变形减振效果、主楼变形影响、阻尼器耗能性能等几个方面综合评定该减振方法的有效性。结果表明,在主楼和裙房(广场)之间采用黏滞阻尼器连接这一方法,不仅能有效地控制因扭转效应过大产生的变形,而且对主楼不会产生不利影响,各阻尼器能在设定的范围正常工作。目前这一减振措施已于2005年成功应用到实际工程中。
The seismic torsional response of the podium structure of the Shanghai Shimao International Plaza is excessively large due to its eccentricity in stiffness and mass distributions. A series of nonlinear time-history analysis are carried out by using the CANNY program to evaluate the reduction method of adopting dampers connecting the podium with the main building. The reduction effect of the podium, the influence on the main building and the dissipative performance of the dampers under different earthquake intensities are analyzed respectively. The results show that using the linking dampers can not only effectively reduce the torsional seismic response of the podium structure, but also have little influence on the seismic performance of main building, and all dampers can function well within the desired scope. The reduction method was already put into use in the year of 2005.
引文
[1]刘晶波,汪勇.主-裙楼结构体系的动力特性及地震反应分析[J].建筑结构学报,2000,21(2):36-43(Liu Jingbo,WangYong.Dynamic properties and seismic response ofhigh-rise building with podium[J].Journal of Building Structure,2000,21(2):36-43(in Chinese))
    [2]DGJ08-9—2003建筑抗震设计规程[S](DGJ08-9—2003Code for seismic design ofbuildings[S](in Chinese))
    [3]Bertero V V.Observations on structural pounding[R]//Pro-ceedings of International Conference on Mexico Earth-quakes,Washington:ASCE,1987:264-278
    [4]Kasai K,Maison B F.Building pounding damage during the1989Loma Prieta Earthquake[J].Engineering Structures,1997,19(3):195-207
    [5]Anagnostopoulos S A.Pounding of building in series during earthquakes[J].Earthquake Engineering and Structural Dynamics,1988,16(3):443-456
    [6]Westermo B D.The dynamics of inter-structural connection to prevent pounding[J].Earthquake Engineering and Structural Dynamics,1989,18(5):687-699
    [7]龚治国,吕西林,卢文胜,等.混合结构体系高层建筑模拟地震振动台试验研究[J].地震工程与工程振动,2004(4):99-105(GongZhiguo,LüXilin,Lu Wensheng,et al.Shaking table model test of a hybrid high-rise building structure[J].Earthquake Engineering and Engineering Vibration,2004(4):99-105(in Chinese))
    [8]Klein R E,Cusano C,Stukel J.Investigation of a method to stabilize wind induced oscillations in large structures(Paper No.72-WA/AUT-H)[C]//Presented at1972ASME Winter Annual Meeting,NewYork:ASME,1972
    [9]Kunieda M.Earthquake prevent design and earthquake proof design for structures[J].Journal of JSME,1976,79(689):86-91(In Japanese)
    [10]Kamagata K,Miyajima K,Seto K.Optimal design of damping devices for vibration control of parallel structures[C]//Proceedings of the3rd International Conference on Motion and Vibration Control.Tokyo:Japan Society of Mechanical Engineers,1996;2:334-339
    [11]Yang Z,Lu X L,Hwu T H,et al.Effect of linking viscous fluid dampers on whipping effect and torsional response of tower-podium systems(Paper No.1022)[C]//Proceedings of the13th World Conference on Earthquake Engineering.Vancouver:Canadian Society for Earthquake Engineering,2004
    [12]Lu X L,Yang Z,Xu Y L.Seismic response control ofadjacent buildings linked by viscous fluid dampers[C]//Proceedings of the3rd International Symposium on Safety Science and Technology:Progress in Safety Science and Technology.Beijing:Science Press,2002:480-487
    [13]Kobori T,Yamada T,Takenaka Y,et al.Effect of dynamic tuned connector on reduction of seismic response applica-tion to adjacent office buildings[C]//Proceedings of the9th World Conference on Earthquake Engineering.Vancouver:Canadian Society for Earthquake Engineering,1988:773-778
    [14]Asano M,Yamano Y,Yoshie K,et al.Development of Active-Damping Bridges and Its Application to Triple High-rise Buildings[J].JSME International Journal,Series C,2003,46(3):854-860
    [15]同济大学结构工程与防灾研究所.世茂国际广场主楼和广场、裙房采用粘滞阻尼器连接减震设计研究报告[R].上海:同济大学结构工程与防灾研究所,2004(Research Institute of structural engineering and disaster reduction,Tongji University.Study report on vibration reduction of fluid linking damper connecting main building with podium for shimao International Plaza[R].Shanghai:Research Institute of structural engineering and disaster reduction,Tongji University,2004(in Chinese))
    [16]CANNY Consultants Pte Ltd.Three-dimensional nonlinear static/dynamic structural analysis computer program[M]//CANNY2004Technical Manual,Singapore:CANNY Con-sultants Pte Ltd.,2003
    [17]翁大根,卢著辉,徐斌,等.粘滞阻尼器力学性能试验研究[J].世界地震工程,2002,18(4):30-34(WengDageng,Lu Zhuhui,Xu Bin,et al.The experimental study on property of energy dissipation of viscous liquid damper[J].World Information on Earthquake Engineering,2002,18(4):30-34(in Chinese))