摘要
目的用重量法取样代替体积取样并研究以质量/质量浓度(mg·g-1)的百分比代替质量/体积浓度(mg·m L-1)的百分比来表示亚甲蓝注射液的含量,为提高其含量测定的准确度、精密度和易操作性提供实验依据。方法用电子天平精密称取一定重量的亚甲蓝注射液,经稀释后用高效液相色谱法(HPLC法)和紫外可见分光光度法(UV-Vis法)测定亚甲蓝注射液的含量,并计算出质量/质量浓度(mg·g-1)百分比。结果重量法取样测定亚甲蓝注射液的含量,测定10次,HPLC法平均含量为99.6%,RSD=0.1%,紫外可见分光光度法平均含量为100.0%,RSD=0.1%;移液取样测定亚甲蓝注射液的含量,测定10次,HPLC法平均含量为99.6%,RSD=0.2%,UV-Vis法平均含量为99.9%,RSD=0.2%。结论重量法取样测定亚甲蓝注射液的含量与以往体积取样相比,测定结果的准确度、精密度和实验易操作性更优,且温度对测定结果的影响更小。
        OBJECTIVE Using weight sampling method instead of pipette sampling method while defining percentage of mass/mass(mg· g-1) as format for representing content of methylthioninium chloride injection,instead of mass/volume(mg· m L-1). To provide experimental support for improving accuracy,precision and operational ease of assay. METHODS Took samples of methylthioninium chloride injection with using electronic balance,determinated assay of it by HPLC method and UV-Vis method after dilution. Then defined percentage of mass/mass(mg·g-1) as format for representing content of it. RESULTS Determinated assay of methylthioninium chloride injection by HPLC method and UV-Vis method,each for ten times. With using weight sampling method,the average content was 99. 6 %,RSD = 0. 1 %,(HPLC method),100. 0 %,RSD = 0. 1 %(UV-Vis method). With using former pipette sampling method,the average content was 99. 6 %,RSD = 0. 2 %(HPLC method),99. 9 %,RSD = 0. 2 %(UV-Vis method). CONCLUSION Compare weight sampling method to former pipette sampling method,the accuracy,precision and operability of assay were better,meanwhile the effect from temperature was diminished.
引文
[1]赵青,韩丽荣.亚甲蓝注射液在骨科手术中的应用[J].护理医学,2006,20(1):229-230.
    [2]陶鑫,陈世伟,王贵国,等.亚甲蓝注射液在肾移植术中的应用[J].临床军医杂志,2005,33(4):452-453.
    [3]鲁松涛.复方亚甲蓝注射液在肛肠术后镇痛中的应用[J].临床医学,2009,29(2):67-68.
    [4]邵文真,孙健,孟凡磊.复方亚甲蓝注射液在肛肠术后镇痛的疗效观察[J].中外医疗,2012,23:108-109.
    [5]唐良振,李贵芹,王运红,等.复方亚甲蓝注射液在乳腺脓肿术后切口镇痛中的疗效观察[J].中国当代医药,2016,23(28):135-138.
    [6]梁亚群.误差理论在化学分析中的应用[J].铜业工程,2006,2:44-46.
    [7]国家药典委员会编.相对密度检查法.中国药典2015年版.四部[S].北京:化学工业出版社,2015,73-74.
    [8]国家药典委员会编.亚甲蓝注射液.中国药典2015年版.二部[S].北京:化学工业出版社,2015,343-344.
    [9]韩淑芹.HPLC法测定亚甲蓝注射液含量及有关物质[J].中国药师,2016,19(4):811-813.
    [10]K.Bergmann,C.T.O'Konski.A spectroscopic study of methylene blue monomer,dimer,and complexes with montmorillonite[J].The journal of physical chemistry,1963,67:2169-2177.