能谱CT优化胃肿瘤扫描辐射剂量对肾上腺嗜铬细胞瘤的诊断价值
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Diagnostic Value of Spectrum CT Optimized Gastric Tumor Scanning Radiation Dose for Adrenal Pheochromocytoma
  • 作者:曹云太 ; 尹桂秀 ; 栗海龙 ; 严小红 ; 鲍海华
  • 英文作者:CAO Yun-tai;YIN Gui-xiu;LI Hai-long;YAN Xiao-hong;BAO Hai-hua;Image Center, Affiliated Hospital of Qinghai University;Intensive Care Unit, Affiliated Hospital of Qinghai University;
  • 关键词:能谱CT ; 胃肿瘤扫描 ; 肾上腺嗜铬细胞瘤 ; 辐射剂量 ; 图像噪声
  • 英文关键词:Spectrum CT;;Gastric tumor scan;;Adrenal pheochromocytoma;;Radiation dose;;Image noise
  • 中文刊名:SWCX
  • 英文刊名:Progress in Modern Biomedicine
  • 机构:青海大学附属医院影像中心;青海大学附属医院重症医学科;
  • 出版日期:2018-11-30
  • 出版单位:现代生物医学进展
  • 年:2018
  • 期:v.18
  • 基金:青海省科技厅科研基金项目(2017-SF-158)
  • 语种:中文;
  • 页:SWCX201822032
  • 页数:4
  • CN:22
  • ISSN:23-1544/R
  • 分类号:152-155
摘要
目的:探讨能谱CT优化胃肿瘤扫描辐射剂量对肾上腺嗜铬细胞瘤的诊断价值。方法:采用回顾性、抽样、随机研究方法选择2012年9月到2017年2月在我院诊治的肾上腺嗜铬细胞瘤患者59例作为研究对象,所有患者都给予常规CT扫描与能谱CT优化胃肿瘤扫描,记录和比较辐射剂量与图像质量。结果:所有病例包膜均完整,边缘清楚,肿瘤内见单发或多发低密度区,肿瘤实质区呈不均匀显著强化。常规CT与能谱CT的图像质量主观评分分别为3.89±0.45分和4.54±0.34分;常规CT与能谱CT图像的胃肿瘤CT值分别为31.94±6.39HU和35.29±5.19HU,对比都有显著差异(P<0.05)。能谱CT图像的膀胱和皮下脂肪图像噪声值都显著低于常规CT图像,对比差异都有统计学意义(P<0.05);能谱CT扫描的CTDIvol和DLP分别为12.39±3.48mGy和624.10±39.19mGy.cm,都显著低于常规CT扫描的14.09±4.13mGy和653.92±56.29mGy.cm(P<0.05)。结论:能谱CT优化胃肿瘤扫描在肾上腺嗜铬细胞瘤诊断中的应用能有效减少辐射剂量与图像噪声,提高图像CT值与主观质量,临床应用价值更高。
        Objective: To explore the diagnostic values of spectrum CT optimized gastric tumor scanning radiation dose for adrenal pheochromocytoma. Methods: A retrospective, randomized study was performed from September 2012 to February 2017, 59 patients of adrenal pheochromocytoma in our hospital were selected as the research object, all patients were given spectrum CT optimized gastric tumor scanning and conventional CT scanning, the radiation dose and image quality were recorded and compared.Results: All patients were showed intact, the edges were clear, single or multiple low density areas were found in the tumor, and the tumor parenchyma were inhomogeneous and significantly enhanced. The subjective scores of image quality of conventional CT and spectrum CT were 3.89±0.45 points and 4.54±0.34 points, respectively. The CT values of gastric tumors in routine CT and spectrum CT images were 31.94± 6.39 HU and 35.29±5.19 HU, respectively, with compared were significantly difference(P<0.05). The bladder and subcutaneous fat image noise values in the spectrum image CT were significantly lower than that of the conventional CT image, the difference were statistically significant(P<0.05); The CTDIvol and DLP in the spectrum image CT were 12.39±3.48 mGy and 624.10±9.19 m Gy.cm were significantly lower than that of the conventional image CT of 14.09±4.13 mGy and 653.92mGy±56.29 mGy.cm(P<0.05). Conclusions: Spectrum CT optimized gastric tumor scanning radiation dose can effectively radiate dose and image noise, improve image CT and subjective quality for adrenal pheochromocytoma, and it has a good application value.
引文
[1]Romanet P,Guerin C,Pedini P,et al.Pathological and Genetic Characterization of Bilateral Adrenomedullary Hyperplasia in a Patient with Germline MAX Mutation[J].Endocr Pathol,2017,28(4):302-307
    [2]Mc Dermott S,Mc Carthy C J,Blake M A.Images of pheochromocytoma in adrenal glands[J].Gland Surg,2015,4(4):350-358
    [3]Stacy G S,Lo R,Montag A.Infarct-Associated Bone Sarcomas:Multimodality Imaging Findings[J].Ajr American Journal of Roentgenology,2015,205(4):432-441
    [4]Brito J P,Asi N,Gionfriddo M R,et al.The incremental benefit of functional imaging in pheochromocytoma/paraganglioma:a systematic review[J].Endocrine,2015,50(1):176-186
    [5]Valentini MC,Mellai M,Annovazzi L,et al.Comparison among conventional and advanced MRI,18F-FDG PET/CT,phenotype and genotype in glioblastoma[J].Oncotarget,2017,8(53):91636-91653
    [6]Bodei L,wikla JB,Kidd M,et al.The role of peptide receptor radionuclide therapy in advanced/metastatic thoracic neuroendocrine tumors[J].J Thorac Dis,2017,9(Suppl 15):S1511-S1523
    [7]Shroff G S,Benveniste M F,Carter B W,et al.Imaging of Metastases in the Chest:Mechanisms of Spread and Potential Pitfalls[J].Semin Ultrasound CT MR,2017,38(6):594-603
    [8]Odisio E G,Marom E M,Shroff G S,et al.Malignant Pleural Mesothelioma:Diagnosis,Staging,Pitfalls and Follow-up[J].Semin Ultrasound CT MR,2017,38(6):559-570
    [9]Yaghobi J A,Azadeh P.Von Hippel-Lindau Disease with Multi-Organ Involvement:A Case Report and 8-Year Clinical Course With Follow-Up[J].Am J Case Rep,2017,17(18):1220-1224
    [10]Heuvelmans M A,Walter J E,Peters R B,et al.Relationship between nodule count and lung cancer probability in baseline CT lung cancer screening:The NELSON study[J].Lung Cancer,2017,11(113):45-50
    [11]Uchida S,Suzuki K,Uno M,et al.Mucin-poor and aggressive mucinous tubular and spindle cell carcinoma of the kidney:Two case reports[J].Mol Clin Oncol,2017,7(5):777-782
    [12]Choi H H,Manning M A,Mehrotra A K,et al.Primary Hepatic Neoplasms of Vascular Origin:Key Imaging Features and Differential Diagnoses With Radiology-Pathology Correlation[J].AJR Am JRoentgenol,2017,209(6):W350-W359
    [13]Couto P P,Bastos R L,Schayek H,et al.Spectrum of germline mutations in smokers and non-smokers in Brazilian non-small-cell lung cancer(NSCLC)patients[J].Carcinogenesis,2017,38(11)1112-1118
    [14]G?tz T I,Lahmer G,Strnad V,et al.A tool to automatically analyze electromagnetic tracking data from high dose rate brachytherapy of breast cancer patients[J].PLo S One,2017,12(9):e0183608
    [15]Hall LT,Titz B,Robins HI,et al.PET/CT imaging of the diapeutic alkylphosphocholine analog(124)I-CLR1404 in high and low-grade brain tumors[J].Am J Nucl Med Mol Imaging,2017,7(4):157-166
    [16]Younan Y,Martinez A,Reimer N,et al.Combined classical spindle cell/pleomorphic lipoma spectrum imaging and clinical data[J]Skeletal Radiol,2018,47(1):51-59
    [17]Schultz T D,Zepeda N,Moore R B.Post-transplan lymphoproliferative disorder and management of residual mass pos chemotherapy:Case report[J].Int J Surg Case Rep,2017,9(38)115-118
    [18]Shakir M,Hanif S,Alam M F,et al.Hybrid pharmacophore approach for bio-relevant di-imines based homobimetallic complexes incorporating functionalized dicarboxylates as co-ligands:Synthesis spectral and structural activity dependent biological insights(in-vitro DNA and HSA binding,antioxidant and cytotoxicity)[J].J Photochem Photobiol B,2017,9(174):106-125
    [19]Krug K B,Houbois C,Grinstein O,et al.Focal Breast Lesions in Clinical CT Examinations of the Chest:A Retrospective Analysis[J]Rofo,2017,189(10):977-989
    [20]Tu S H,Hsieh Y C,Huang L C,et al.A rapid and quantitative method to detect human circulating tumor cells in a preclinical animal model[J].BMC Cancer,2017,17(1):440
    [21]Heuvelmans M A,Vliegenthart R,Koning H J,et al.Quantification of growth patterns of screen-detected lung cancers:The NELSONstudy[J].Lung Cancer,2017,7(108):48-54
    [22]Krupa R,Zielonka T M,Hadzik B M,et al.Lung Lesions During Fever of Unknown Origin[J].Adv Exp Med Biol,2017,10(22):35-43
    [23]Tassi R A,Todeschini P,Siegel E R,et al.FOXM1 expression is significantly associated with chemotherapy resistance and adverse prognosis in non-serous epithelial ovarian cancer patients[J].J Exp Clin Cancer Res,2017,36(1):63-69
    [24]Planells P V,Hazazi A,Feichtinger J,et al.Human germ/stem cell-specific gene TEX19 influences cancer cell proliferation and cancer prognosis[J].Mol Cancer,2017,16(1):84-89
    [25]Bhatt S,Sumbul M,Rajpal R,et al.Value of"Three Dimensional Multidetector CT Hysterosalpingography"in Infertile Patients with Non-Contributory Hysterosalpingography:A Prospective Study[J].JReprod Infertil,2017,18(3):323-332
    [26]Jelvehgaran P,Alderliesten T,Weda JJA,et al.Visibility of fiducial markers used for image-guided radiation therapy on optical coherence tomography for registration with CT:An esophageal phantom study[J].Med Phys,2017,44(12):6570-6582
    [27]Mansor S,Pfaehler E,Heijtel D,et al.Impact of PET/CT system,reconstruction protocol,data analysis method,and repositioning on PET/CT precision:An experimental evaluation using an oncology and brain phantom[J].Med Phys,2017,44(12):6413-6424
    [28]Teoh E J,Mcgowan D R,Macpherson R E,et al.Phantom and Clinical Evaluation of the Bayesian Penalized Likelihood Reconstruction Algorithm Q.Clear on an LYSO PET/CT System[J].Journal of Nuclear Medicine Official Publication Society of Nuclear Medicine,2015,56(9):1447-1452
    [29]Samarin A,Kuhn F P,Brandsberg F,et al.Image registration accuracy of an in-house developed patient transport system for PET/CT+MR and SPECT+CT imaging[J].Nuclear Medicine Communications,2015,36(2):194-200