电厂循环冷却水化学稳定处理试验研究
详细信息    本馆镜像全文|  推荐本文 |  |   获取CNKI官网全文
摘要
循环冷却水系统是电厂水量最大、水质最为复杂的用水系统,系统运行的稳定性对电厂安全经济运行具有重要影响。本论文结合国华余姚燃气发电厂循环冷却水系统特点和水质实际情况,通过动态模拟试验和旋转挂片试验考察了药剂种类、加入量、运行方式等因素对循环冷却水系统运行的影响;对药剂选型和药剂量进行了优化;得到了系统安全运行的化学稳定处理方案和极限浓缩倍率。试验结果显示:采用低磷、高阻垢性、高缓蚀性的缓蚀阻垢剂配方处理电厂的循环冷却水方案是可行的,论文结果为国华余姚燃气发电厂工程循环冷却水运行管理提出了切实可行的方案。
Circulating cooling water is one of the most important and the most complicated consumption in power station. And the stability of operating system in power plant has an important impact on economic performance and safety.According to the actual circulating water quality of power plant.This article makes series of researches on the actual circulating water yreatment technique through dynamic simulation test and test-spin pegged in Yu Zao Power Plants.And the research concludes the effect factors and the water system style;concludes the concentrate rate and the run method ,and so on .The results of experiment to prevent scale and decelerate corrosion are summarized comprehensively. Scale and corrosion can be restrained effectively by treating circulating water by the reagent prescribed low phosphorus content and highly anti-scale and anti-corrosion components.
引文
[1] HG/T 2160—91 冷却水动态模拟试验方法
    [2] GB/T 18175—2000 水处理剂缓蚀性能的测定 旋转挂片法
    [3] GB/T 16632—1996 水处理剂阻垢性能的测定 碳酸钙沉积法
    [4] GB/T 4789.2—1994 食品卫生卫生学检验 菌落总数测定
    [5] DL/T 712—2000 火力发电厂凝汽器管选材导则
    [6] DL/T 806—2002 火力发电厂循环冷却水用阻垢缓蚀剂
    [7] 美国材料试验协会标准 “ASTM A249/A249M-03 Standard Specification for Welded Austenitic Steel Boiler,Superheater,Heat Exchang,and Condenser Tubes”
    [8] 李进,许兆义,于海琴.微滤/反渗透处理、回用循环冷却排水[J].中国给水排水,2004,20(9):47~49
    [9] 工业水处理药剂手册[M].栗田工业水处理药剂手册编制委员会,2000
    [10] J.W.麦科伊.冷却水的化学处理[M].北京:化学工业出版社,2001
    [11] 刘洪升.高参数机组电厂化学水处理技术发展探讨[J].电厂电站设备,2004,(4)
    [12] 肖锦.城市污水处理及回用技术[M].北京:化学工业出版社,2002
    [13] 曲政,庞其伟,等.滨海电厂钢质海水管道的选材和防护[J].热力发电,2004, 33 (10)
    [14] 朱志良,邓守权,倪亚明.PBTCA 与 Cu、Zn、Cd、Ni 离子间的配位化学研究[J].工业水处理,2002,22(1):23~25
    [15] 沈丽娜,完颜萍.循环冷却水杀菌剂的发展[J].甘肃科技,2003(8):153~171
    [16] 解群,梁磊.冷却水中 SO42-对不锈钢管的缓蚀作用[J].上海电力学院学报, 2000,2(6):33~36
    [17] Macdonald D D,SyrettB C,W ing S S.Corrosion of Cu-Nickel alloys706 and 715 in flowing seawater.Ⅱ Effect of dissolved sulfide[J].Corrosion,1979,35(8):367~377
    [18] MacdonaldD D,SyrettB C,W ing S S.Corrosion of Cu-nickel alloys in sea water polluted with sulfide and sulfide oxidation products[J].Corrosion,1979,35(9):409~422
    [19] AL — Hajji JA, RedaM R . Corrosion of Cu-Ni-Alloysin Sulfide — Polluted Seawater[J].Corrosion,1993,49(10):809~820
    [20] 郭丽彩.火力发电厂循环冷却水杀菌处理方式探讨[J].河北电力技术,2001(2):78~86
    [21] Milosev IM,VicM H,DrogowskaM,et al.Brosard breakdown of passive film on copper in bicarbonate solution containing sulfate lions[J].Electrochem Soc,1992,139(9):2409~2418
    [22] Okazaki M,et al.Water recycling using sequential membrane treatment in electronics industry[J].Desalination,2000,131:65~73
    [23] Marcus P.Surface science approach of corrosion phenomena[J].ElectrochimicaActa,1998,43(112):109~118
    [24] FengY,Siow K S,TeoW K,et al.CorrosionMechanisms and Products of Copper in Aqueous Solutions at Various pH Values[J].Corrosion,1997,53(5):389~398
    [25] 高秀山.火电厂循环冷却水处理[M].北京:中国电力出版社,2001:27~41,82~86
    [26]何高荣,陈博武,蒋毅章等.PAPEMP 与西部冷却水处理[J].工业水处理,2002,22(1):19~22
    [27] 李本高,祁鲁梁,李永存.石化工业水处理技术进展[M].北京:中国石化出版社,1999:80~85
    [28] 吴宇峰,周坤坪,梁劲翌.绿色环保软化水缓蚀剂的研制[M].工业水处理,2000,20(2):31~33
    [29] 杨亚玲,毕莉,等.水质稳定剂 PHMA 缓蚀性能的研究[J].水处理技术,2003,5(6):12~23
    [30] 余学军,王战铃.循环冷却水杀菌剂的比较与发展方向[J].宁夏电力,2005
    [31] C.C.Nathan.Corrosion Inhibitors[M].National Association of Corrosion Engineers.Houston Taxas,1973
    [32] Tosa T,Mori T,Fuse N et al.Enzymologia,1967,32(3):153~164
    [33] 徐峰,蔡娟.反渗透工艺处理电厂循环冷却排污[J].给水排水,2004,30(6): 40~42
    [34] 周柏青.电厂化学[M].北京:中国电力出版社,2003:194~212
    [35] 崔玉川,董辅祥.城市与工业节约用水手册[M].北京:化学工业出版社,2003:332~347
    [36] Ruta Rakutis.Water Management Chemieals.SPeeial Chemieals,1987,32(4):71~79
    [37] 齐冬子.敞开式循环冷却水系统的化学处理[M].化学工业出版社,2003
    [38] 张振家,郭晓燕,周长波.工厂废水处理工艺原理与维护管理[M].北京:化学工业出版社,2003