摘要
针对不满足抗震性态目标的一栋四层钢筋混凝土框架填充墙结构,基于框架和填充墙的抗震性态目标,采用附加阻尼器的被动控制方法进行抗震加固分析研究。首先,提出两种被动控制加固方案:1.在一层所有填充墙平面内方向上并联阻尼器进行抗震加固;2.在一层和二层所有填充墙平面内方向上并联阻尼器进行抗震加固;其次,基于Open Sees有限元软件,建立上述两种被动控制加固方案的有限元模型,选取El Centro、Parkfield和San Fenando三条地震动进行罕遇地震作用下的地震反应分析;最后,依据使用功能为钢筋混凝土框架填充墙结构抗震性态目标的量化指标,即综合考虑层间位移角限值和填充墙破坏情况,判定四层钢筋混凝土框架填充墙结构采用加固方案二可满足抗震性态目标的要求。
In this paper,a four- storey reinforced concrete frame infilled wall structure does not meet the seismic perform target,based on the seismic behavior target of both frame and infilled wall,to carry out the study on the passive control seismic strengthen of RC infilled wall structure with attached dampers. First,two kinds of passive control strengthen schemes were put forward. 1. Dampers were installed in the in- plane direction parallel with all 1- storey infilled walls; 2. Dampers were installed in the in- plane direction parallel with all 1- storey and 2- storey infilled walls.Then to establish the two types of passive control seismic strengthen model in Open Sees,then carry out the rare earthquake nonlinear time- history analysis under El Centro,Parkfield and San Fenando ground motions. Finally,in accordance with the seismic performance target quantization index of RC Frame infilled wall structure used,i. e. considering drift angle limit and infilled wall damage,judge the scheme 2 can meets the seismic performance target.
引文
[1]工业与民用建筑抗震设计规范(TJ11-78)[S].中国建筑工业出版社,北京:1978The Code for seismic design of Industrial and civil buildings(TJ11-78),pubilshed by China Architecture&Building Press in Beijing(1978)
[2]建筑工程抗震性态设计通则(CECS 160:2004)[S].中国计划出版社,北京:2004General rule for performance-based seismic design of buildings(CECS 160:2004),pubilshed by China Planning Press in Beijing(2004)
[3]建筑工程抗震设防分类标准(GB 50223-2008)[S].中国建筑工业出版社,北京:2008Standard for classification of seismic protection of building constructions,published by China Architecture&Building Press in Beijing(2008)
[4]建(构)筑物地震破坏等级划分(GB/T 24335-2009)[S].中国建筑工业出版社,北京:2009Classification of earthquake damage to buildings and special structures(GB/T 24335-2009),pubilshed by China Architecture&Building Press in Beijing(2009)
[5]李科,魏延良.钢筋混凝土结构的抗震加固方法述评[J].地震工程与工程振动,2005,25(4):126-129Li ke,Wei Yanliang,Review of seismic retrofit methods of reinforced concrete structures,Earthquake Engineering and Engineering Vibration 25(4),p.126-129,2005
[6]刘鸣.结构振动控制的应用及若干问题[J].长安大学学报,2003,20(4):5-7.Liu Ming,Application and some problems of structural vibration control,Journal of Chang'an University,2003,20(4):5-7.
[7]薛彦涛,范苏榕.传统抗震加固技术与抗震加固新技术的介绍[J].工程建设与设计,2006,(8):19-22.Xue Yantao,Fan Surong,Reviews on Seismic Strengthening of Existing Structures in Our Country,Construction&design For Project,(8):19-22,2006.
[8]肖志.钢筋混凝土框架结构抗震鉴定及消能减震加固方法的研究[D].重庆:重庆大学,2006.Xiao Zhi,the Study on Seismic Appraiser and Energy Dissipation and Vibration Absorption Retrofit Method of RC Frame Structure,Chong Qing University in Chong Qing,2006.
[9]杨君.钢筋混凝土框架结构基于性能的抗震设计理论和方法[D].西安:西安建筑科技大学,2007.Yang Jun,Displacement-Based Design Theory and Method of Reinforced Concrete Frame Structure[D],in Xi’an University of Architecture and Technology in Xi’an(2007)
[10]张敬书,潘宝玉.现行抗震加固方法及发展趋势[J].工程抗震与加固改造,2005,27(1):56-62.Zhang Jingbao,Pan Baoyu,Methods and Development of Present Aseismic Retrofitting,Earthquake Resistant Engineering and Retrofitting,2005,27(1):56-62.
[11]Hashemi,S.A.and Mosalam,K.M.(2007),Seismic Evaluation of Reinforced Concrete Buildings Including Effects of Infill Masonry Walls,Pacific Earthquake Engineering Research Center,PEER 2007/100.
[12]褚春雨,框架填充墙结构被动控制抗震加固分析[M],中国地震局工程力学研究所,2012.
[13]Chu Chunyu,the study on infilled walls effect in RC Frame infilled wall structure[M],Institute of Engineering Mechanics,CEA,Harbin,2012