用户名: 密码: 验证码:
The Ahmed Versus Baerveldt Study: Five-Year Treatment Outcomes
详细信息    查看全文
文摘
To compare 2 frequently used aqueous shunts for the treatment of glaucoma.

Design

International, multicenter, randomized trial.

Participants

Patients aged 18 years or older with uncontrolled glaucoma despite maximum tolerated medical therapy, many of whom had failed or were at high risk of failing trabeculectomy.

Methods

Eligible patients were randomized to receive an Ahmed-FP7 valve implant (New World Medical, Inc, Rancho Cucamonga, CA) or a Baerveldt-350 implant (Abbott Medical Optics, Inc, Santa Ana, CA) using a standardized surgical technique.

Main Outcome Measures

The primary outcome was failure, defined as intraocular pressure (IOP) outside the target range (5–18 mmHg) or reduced <20% from baseline for 2 consecutive visits after 3 months, severe vision loss, or de novo glaucoma surgery. Secondary outcomes measures included IOP, medication use, visual acuity, complications, and interventions.

Results

A total of 238 patients were randomized; 124 received the Ahmed-FP7 implant, and 114 received the Baerveldt-350 implant. Baseline characteristics were similar between groups. Mean preoperative IOP was 31.4±10.8 mmHg on 3.1±1.0 glaucoma medications. At 5 years, the cumulative failure rate was 53% in the Ahmed group and 40% in the Baerveldt group (P = 0.04). The main reason for failure in both groups was high IOP, and the cumulative de novo glaucoma reoperation rate was 18% in the Ahmed group and 11% in the Baerveldt group (P = 0.22). Hypotony resulted in failure in 5 patients (4%) in the Baerveldt group compared with none in the Ahmed group (P = 0.02). Mean IOP was 16.6±5.9 mmHg in the Ahmed group (47% reduction) and 13.6±5.0 mmHg in the Baerveldt group (57% reduction, P = 0.001). Mean medication use was 1.8±1.5 mmHg in the Ahmed group (44% reduction) and 1.2±1.3 mmHg in the Baerveldt group (61% reduction, P = 0.03). The 2 groups had similar complication rates (Ahmed 63%, Baerveldt 69%) and intervention rates (Ahmed 41%, Baerveldt 41%). Most complications were transient, and most interventions were slit-lamp procedures.

Conclusions

Both implants were effective in reducing IOP and the need for glaucoma medications. The Baerveldt group had a lower failure rate and a lower IOP on fewer medications than the Ahmed group, but had a small risk of hypotony that was not seen in the Ahmed group.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700