A novel spraying/negative-pressure secondary dust suppression device used in fully mechanized mining face: A case study
详细信息    查看全文
文摘
Aiming at improving the spraying dust suppression performances between the coal cutter hydraulic supports, a novel spraying/negative-pressure secondary dust suppression device was developed. In this device, the nozzle's atomization performance including atomizing angle, spraying range and droplet diameter were measured so as to select the optimal nozzle. A nozzle with optimal overall atomization performance was selected among 4 kinds of nozzles with hollow and solid cone-shaped spraying fields. At the optimal spraying pressure of 8 MPa, the spraying field of the developed dust suppression device can almost cover all the space between coal walls and hydraulic support's columns, and effectively absorb the dusty airflow in the footway. Field measurements indicated that, compared with the original dedusting method, the dust suppression rates of total coal dust and respirable dust in the fully mechanized mining face by the developed novel spraying device can be enhanced by 26.2% and 27.3% respectively and reach efficiencies up to 82.0% and 80.9%, respectively. The dust suppression rates of total coal dust and respirable dust in the working area for supports moving workers can be enhanced to 81.5% and 80.1%, respectively.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700