用户名: 密码: 验证码:
Magnetic source imaging in non-lesional neocortical epilepsy: Additional value and comparison with ICEEG
详细信息查看全文 | 推荐本文 |
摘要

Objective

To investigate the utility of magnetic source imaging (MSI) for localizing the epileptogenic zone (EZ) and predicting epilepsy surgery outcome in non-lesional neocortical focal epilepsy (NLNE) patients.

Methods

Data from 18 consecutive patients with NLNE who underwent presurgical evaluation including intracranial electroencephalography (ICEEG) and MSI were studied. Follow-up after epilepsy surgery was 鈮?#xA0;24 months. Intracranial electroencephalography and MSI results were classified using a sublobar classification.

Results

Sublobar ICEEG focus was completely resected in 15 patients; seizure-free rate was 60%. Eight patients showed sublobar-concordant ICEEG/MSI results and complete resection of both regions; seizure-free rate was 87.5%. Seizure-free rate in cases not matching these criteria was only 30%(p = 0.013).

Conclusions

Magnetoencephalography is a useful tool to localize the EZ and determine the site of surgical resection in NLNE patients. When sublobar concordance with ICEEG is observed, MSI increases the predictive value for a seizure-free epilepsy surgery outcome in these patients.