供水泵站变频调速系统节能运行研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Research on Energy-Saving Operation of Variable Frequency Speed Regulation System for Water Supply Pump Station
  • 作者:路文梅 ; 彭程 ; 陈欢欢 ; 刘风华
  • 英文作者:LU Wen-mei;PENG Cheng;CHEN Huan-huan;LIU Feng-hua;College of Electrical Engineering,Hebei University of Water Resources and Electric Engineering;College of Hydraulic Engineering,Hebei University of Water Resources and Electric Engineering;
  • 关键词:供水泵站 ; 单方水耗电量 ; 变频调速 ; 节能运行 ; 效率
  • 英文关键词:water supply pump station;;unilateral water consumption;;variable frequency speed regulation;;energy-saving operation;;efficiency
  • 中文刊名:SDNY
  • 英文刊名:Water Resources and Power
  • 机构:河北水利电力学院电气工程学院;河北水利电力学院水利工程学院;
  • 出版日期:2018-11-25
  • 出版单位:水电能源科学
  • 年:2018
  • 期:v.36;No.219
  • 基金:河北省水利厅项目(201669);; 河北省教育厅项目(QN2018220)
  • 语种:中文;
  • 页:SDNY201811041
  • 页数:5
  • CN:11
  • ISSN:42-1231/TK
  • 分类号:86+171-174
摘要
为了探究供水泵站变频调速系统的最佳节能运行方式,以单方水耗电量为考核目标,通过对供水系统工作原理的分析,并以供水泵站设备及系统实测数据为依据,利用Matlab软件拟合数学方程及曲线,以沧州泊头供水泵站为例,分析了供水系统能量损失原因及能量损失分布情况,提出了相同工况不同运行方式下的效率模型,计算并比较不同方案的单方水耗电量,确定了最佳运行方案。结果表明,相同工况下选择最优运行方案可达到提高供水效率,降低能耗的目的。
        In order to explore the optimized energy-saving operation mode of variable frequency speed regulation system for water supply pump station,taking unilateral water consumption as the assessment target,the operation principle of water supply system was analyzed.Based on the measured data of the water supply pump station system,the Matlab was used to fit the mathematical equations and curves.Taking the Botou water supply pump station in Cangzhou as an example,the energy loss and distribution of the water supply system were analyzed.The efficiency model was put forward under the same operating conditions.The unilateral water consumption of different schemes was calculated and compared,and the optimal operation scheme was determined.The results show that the optimal operation scheme under the same working conditions can improve the efficiency of water supply and reduce energy consumption.
引文
[1]王立.我国泵系统节能的现状及发展前景[J].水泵技术,2012(1):28-30.
    [2]董晓莉,胡生彬,狄兵兵.变频调速对水泵经济运行的影响分析[J].电气应用,2012,31(4):79-83.
    [3] Clemente S.A Simple Tool for the Selection of IGBTs for Motor Drives and UPSs[C]//Conf.Rec.of IEEE Applied Power Electronics Conference and Exposition,1995:755-764.
    [4]张玉胜,吴建华,刘慧如,等.具有变频泵的泵站经济运行方式研究[J].水电能源科学,2015,33(4):163-166.
    [5]周龙才,李娜.大型泵站双调机组的工况调节优化计算[J].水电能源科学,2014,32(5):144-147.
    [6]张承慧,夏东伟,石庆升.计及变频器和电机损耗的全变速泵站效率优化控制[J].电工技术学报,2006,21(5):52-57.
    [7]罗杰.普通交流异步电动机变频调速的性能研究[D].贵阳:贵州大学,2006.
    [8]刘波,霍亭,方修睦,等.水泵装置的效率分析及试验研究[J].区域供热,2018(1):85-91

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700