用户名: 密码: 验证码:
城市供水泵站启停机对前池涌浪的影响
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Impact of startup and shutdown on surge in forebay of urban water supply pumping station
  • 作者:胡建永 ; 杨飞
  • 英文作者:HU Jianyong;YANG Fei;Department of Hydraulic Engineering,Zhejiang University of Water Resources and Electric Power;Hydro China Huadong Engineering Corporation;
  • 关键词:泵站 ; 前池 ; 波动周期 ; 涌浪叠加 ; 启停机
  • 英文关键词:pumping station;;forebay;;fluctuation cycle;;surge superposition;;startup and shutdown
  • 中文刊名:SJWJ
  • 英文刊名:Water Resources and Hydropower Engineering
  • 机构:浙江水利水电学院水利工程系;中国水电顾问集团华东勘测设计研究院;
  • 出版日期:2013-12-20
  • 出版单位:水利水电技术
  • 年:2013
  • 期:v.44;No.482
  • 基金:中国博士后科学基金资助项目(20100481081);; 江苏省博士后科研资助计划项目(1101020C);; 国家自然科学基金项目(51079050)
  • 语种:中文;
  • 页:SJWJ201312031
  • 页数:4
  • CN:12
  • ISSN:11-1757/TV
  • 分类号:123-125+132
摘要
在调压室理论基础上,分析了泵站前池涌浪的波动周期和规律,并据此得出了单泵和多泵运行工况下,水泵不同时间间隔启停机的涌浪叠加效果。研究表明,数值计算结果与理论分析的规律一致,前池最不利的涌浪叠加时刻为上游管道流量的最大(小)时刻,该时刻对应前池水位变化梯度最大的时刻。在单台水泵进行启停机操作时,泵站其他正常运行机组的台数越多,越有利于平抑因该台水泵启停机而产生的前池涌浪叠加幅值。
        Based on the theory of surge-chamber,the cycle and law of fluctuation of the surge in the forebay of pumping station are analysed herein. On the basis of this,the superposed effects from various time intervals of the startup and shutdown of pumping station on the surge in the forebay under the single or multi-pump operation conditions are obtained. The study shows that the law got from the numerical calculation coincides with that from the theoretical analysis,i. e. the most unfavorable moment of the surge superposition in the forebay is just the moment when the flow rate inside of the upstream pipeline is the maximum( or the minimum),while this moment is corresponding to the moment of the maximum of the water level changing gradient. When only a single pump starts up and shuts down,the more the pumping units operate in the pumping station,the favorable for restraining the amplitude of the surge superposition in the forebay caused by that pump will be.
引文
[1]李静毅,李国平,王如华.五号沟泵站调试过程前池水位波动分析[J].给水排水,2011,37(6):17-21.
    [2]徐辉.城市排水泵站进水水力特性研究[D].南京:河海大学,2008.
    [3]冯建刚,李杰.大型城市水源泵站前池流态及改善措施试验[J].水利水电科技进展,2010,30(2):70-74.
    [4]Wylie E B,Streeter V L,Suo Lisheng.Fluid Transient in Systems[M].New Jersey:Prentice Hall,1993.
    [5]程永光,陈鉴治,杨建东.水电站调压室涌浪最不利叠加时刻的研究[J].水利学报,2004(7):109-113.
    [6]李高会,张健,齐央央,等.阻抗上室式调压室突弃全负荷时涌浪的解析解[J].水电能源科学,2009,27(3):55-57.
    [7]张永良,缪明非.组合工况下阻抗式调压室涌浪计算的显式公式[J].水利学报,2012,43(4):467-472.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700