用户名: 密码: 验证码:
托卡马克弯晶谱仪双晶体结构应用的初步研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Preliminary study on double-crystal for X-ray curved-crystal spectrometer on EAST
  • 作者:陈俊 ; 吕波 ; 王福地 ; 潘夏云 ; 李颖颖 ; 符佳 ; 尹相辉 ; 胡睿佶 ; 冯双园 ; 石跃江 ; 余羿 ; 叶民友
  • 英文作者:CHEN Jun;LYU Bo;WANG Fudi;PAN Xiayun;LI Yingying;FU Jia;YIN Xianghui;HU Ruiji;FENG Shuangyuan;SHI Yuejiang;YU Yi;YE Minyou;School of Nuclear Science and Technology, University of Science and Technology of China;Institute of Plasma Physics, Chinese Academy of Sciences;Department of Nuclear Engineering, Seoul National University;
  • 关键词:等离子体诊断 ; 弯晶谱仪 ; 双晶体 ; 多普勒展宽
  • 英文关键词:Plasma diagnostic;;Crystal spectrometers;;Double crystal;;Doppler broadening
  • 中文刊名:HJSU
  • 英文刊名:Nuclear Techniques
  • 机构:中国科学技术大学核科学技术学院;中国科学院等离子体物理研究所;首尔大学核工程系;
  • 出版日期:2015-11-10
  • 出版单位:核技术
  • 年:2015
  • 期:v.38
  • 基金:国家国家磁约束核聚变发展研究专项(No.2012GB101001;No.2013GB112004;No.2015GB101001);; 国家自然科学基金(No.11175208;No.11275233;No.11405212);; 中日韩A3前瞻计划项目(No.11261140328);; 合肥物质科学技术中心方向项目培育基金(No.2014FXCX003)资助
  • 语种:中文;
  • 页:HJSU201511010
  • 页数:5
  • CN:11
  • ISSN:31-1342/TL
  • 分类号:67-71
摘要
X射线弯晶谱仪作为托卡马克装置等离子体温度和旋转速度等参数诊断测量的重要手段之一,通常利用单晶体衍射分光来测量某种特定杂质的特征谱,这也限制了弯晶谱仪所能测量的等离子体温度范围。为解决更高温度等离子体测量问题,有效提高目前弯晶谱仪诊断系统温度测量范围,用双晶体代替原有单晶体,通过选择合适的晶体和Bragg衍射角组合,利用同一个探测器同时测量类氢和类氦的氩离子光谱,实现更高更宽温度范围测量。本文就东方超环(Experimental Advanced Superconducting Tokamak,EAST)弯晶谱仪双晶体应用方面的设计和技术实现进行了阐述,并首次在EAST装置上成功实现了氩离子类氦和类氢谱线的测量,利用类氦线和类氢线拟合得到的氩离子温度非常接近,验证了双晶体结构的可行性。
        Background: X-ray curved-crystal spectrometer, as one of important diagnostic tool for measuring the plasma temperature and rotation velocity of the tokamak, is usually based on the satellite spectra of some special kind of impurity by single-crystal diffraction, which limits the temperature range to be measured simultaneously. Purpose: This study aims to effectively broaden the temperature range of the spectrometers, an assembly of double-crystal was designed to replace the previous of single-crystal. Methods: The two crystals of the assembly having the similar Bragg angles were installed on the same pedestal, which could make the spectra recorded on the same detector. Consideration and technology route of the double-crystal were described and analyzed together with the experimental tests on the Experimental Advanced Superconducting Tokamak(EAST). Results: Experimental results on the double-crystal X-ray spectrometer showed that the He-like and H-like Ar spectra were obtained for the first time, and the ion Ar temperatures calculated by two kinds of spectra were in good consistence within a certain error range. Conclusion: The application of double-crystal for X-ray curved-crystal spectrometers on EAST proposed in this paper is applicable and feasible.
引文
1 Bitter M,Von Goeler S,Horton R,et al.Doppler-broadening measurements of X-ray lines for determination of the ion temperature in tokamak plasmas[J].Physical Review Letters,1979,42(5):304 -307.DOI:10.1103/Phys Rev Lett.42.304
    2 Bitter M,Fraenkel B,Hill K W,et al.Numerical studies of the imaging properties of doubly focussing crystals and their application to ITER[J].Review of Scientific Instruments,1995,66(1):530-532.DOI:10.1063/1.1146341
    3 Shi Y J,Wang F D,Wan B N,et al.Imaging X-ray crystal spectrometer on EAST[J].Plasma Physics and Controlled Fusion,2010,52(8):085001-085014.DOI:10.1088/0741-3335/52/8/085014
    4 Lee S G,Bak J G,Bitter M,et al.Imaging X-ray crystal spectrometers for KSTAR[J].Review of Scientific Instruments,2003,74(3):1997-2000.DOI:10.1063/1.1535243
    5 Bitter M,Hill K W,Stratton B,et al.Spatially resolved spectra from a new X-ray imaging crystal spectrometer for measurements of ion and electron temperature profiles(invited)[J].Review of Scientific Instruments,2004,75 (10):3660-3665.DOI:10.1063/1.1791747
    6 Hill K W,Bitter M L,Scott S D,et al.A spatially resolving X-ray crystal spectrometer for measurement of ion-temperature and rotation-velocity profiles on the Alcator C-Mod tokamak[J].Review of Scientific Instruments,2008,79(10):10E320.DOI:10.1063/1.2969080
    7 Hill K W,Bitter M,Delgado-Aparicio L,et al.Development of a spatially resolving X-ray crystal spectrometer for measurement of ion-temperature(T(i))and rotation-velocity(v)profiles in ITER[J].Review of Scientific Instruments,2010,81(10):10E322.DOI:10 .1063/1.3492414
    8 Lu B,Wang F,Shi Y,et al.Upgrades of the high resolution imaging X-ray crystal spectrometers on experimental advanced superconducting tokamak[J].Review of Scientific Instruments,2012,83(10):10E130.DOI:10.1063/1.4738652
    9 Marchuk O.Modeling of He-like spectra measured at the TMarchuk,modeling of He-like spectra measured at the tokamak TEXTOR and TORE SUPRAEXTOR and SUPRA[D].Jülich:Ruhr-Universit?t Bochum,2004

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700