摘要
介绍了全国辐射环境监测网络放射性气溶胶中γ核素测量考核情况及其结果分析。采用稳健统计方法处理测量结果表明,87.8%的测量值为满意结果,6.1%的测量值为有问题结果,6.1%的测量值为离群。通过比较测量结果的中位值与参考值,发现各核素测量值可能存在负的系统误差。利用此次考核,基本了解了全国辐射环境监测网络气溶胶中γ核素测量水平,为进一步做好网络质保工作提供了依据。
The results for gamma nuclides in aerosol in State Environmental Radiation Monitoring Network Measurement Assessment Program in 2013,held by the Environmental Radiation Monitoring Station of Zhejiang Province,were presented. With robust statistical method employed,it showed that 87. 8% of measurement results were satisfied,6. 1% were dubitable,and remaining 6. 1% dissatisfied. Comparison of the resulted median and the reference values indicated there may be a negative system error for the measurements of every nuclide. With this program,the measurement capability of gamma nuclides in aerosol in the network was generally understood,which provided a basis for the future quality assurance in the respect.
引文
[1]周程,张起虹,蒋云平,等.大气中放射性气溶胶的监测和评价[J].核技术,2011,34(11):866.
[2]陈亮.大气中放射性气溶胶滤膜过滤效率的测定[J].资源节约与环保,2013,10:15.
[3]中华人民共和国国家标准.用半导体γ谱仪分析低比活度γ放射性样品的标准方法[S].GB/T11713—1989.
[4]中华人民共和国卫生行业标准.空气放射性核素的γ能谱分析方法[S].WS/T 184—1999.
[5]中华人民共和国国家标准.土壤中放射性核素的γ能谱分析方法[S].GB 11743—1989.
[6]中华人民共和国国家标准.利用实验室间比对的能力验证第1部分:能力验证计划的建立和运作[S].GB 15483.1—1999.
[7]中国合格评定国家认可委员会.能力验证结果的统计处理和能力评价指南[Z].CNAS-GL02,2006.
[8]陆继根,王凤英.γ能谱仪对1995年固体样的比对试验[J].环境监测管理与技术,1997,9(4):23.
[9]张佳媚,常永富,师全林,等.一台反康普顿HPGeγ谱仪的性能改造和应用[J].核电子学和探测技术,2004,24(2):172.