磁共振兼容心脏植入型电子器械临床应用中的有关问题
详细信息    查看全文 | 推荐本文 |
摘要
磁共振(MRI)兼容心脏植入型电子器械(CIED)植入后允许有条件的行MRI检查。有研究显示CIED行急诊头颅MRI检查对急性卒中的诊断和治疗是可行的、安全的。国内多家大的医院研究数据显示MRI兼容CIED植入后MRI检查率低于国外研究的数据。目前国内外研究均证实MRI兼容CIED植入后行MRI检查安全且有效。
        
引文
1 Celentano E,Caccavo V,Santamaria M,et al.Access to magnetic resonance imaging of patients with magnetic resonance-conditional pacemaker and implantable cardioverter defibrillator systems:results from the Really ProMRI study[J].Europace,2018,20(6):1 001
    2 陈若菡,陈柯萍,华伟,等.磁共振兼容心血管植入型电子器械临床应用调查[J].中华心律失常学杂志,2017,21(2):95
    3 陈学颖,柏瑾,王蔚,等.磁共振兼容起搏器的单中心植入现状分析[J].中华心律失常学杂志,2017,21(2):107
    4 Ono M,Suzuki M,Isobe M,et al.Feasibility,safety,and potential demand of emergent brain magnetic resonance imaging of patients with cardiac implantable electronic devices [J].J Arrhythm,2017,33(5):455
    5 Ching CK,Chakraborty RN,Kler TS,et al.Clinical safety and performance of a MRI conditional pacing system in patients undergoing cardiac MRI[J].Pacing Clin Electrophysiol,2017,40(12):1389
    6 吴冬燕,卢凤民,李琼,等.磁共振兼容起搏器的临床应用评价[J].中华心律失常学杂志,2017,21(2):103
    7 陈涵,项美香.磁共振兼容心脏植入型电子器械临床应用分析[J].中华心律失常学杂志,2017,21(2):99
    8 胡竹君,史嘉然,胡静静,等.磁共振成像兼容起搏器临床应用随访[J].心脑血管病防治,2018,18(5):382
    9 李腾,徐琼,黄俊,等.兼容核磁共振双腔心脏起搏器植入的临床应用研究[J].中国心脏起搏与心电生理杂志,2018,32(5):446
    10 徐强,屈百鸣.心脏起搏器和转复除颤器植入后的磁共振检查—从绝对禁忌症到允许有条件检查[J].中国心脏起搏与心电生理杂志,2009,23(3):250
    11 Gold MR,Sommer T,Schwitter J,et al.Full-body MRI in patients with an implantable cardioverter-defibrillator:primary results of a randomized study[J].J Am Coll Cardiol,2015,65(24):2 581
    12 Awad K,Griffin J,Crawford TC,et al.Clinical safety of the Iforia implantable cardioverter-defibrillator system in patients subjected to thoracic spine and cardiac 1.5-T magnetic resonance imaging scanning conditions[J].Heart Rhythm,2015,12(10):2 155
    13 Kypta A,Blessberger H,Hoenig S,et al.Clinical safety of an MRI conditional implantable cardioverter defibrillator system:A prospective Monocenter ICD-Magnetic resonance Imaging feasibility study(MIMI)[J].J Magn Reson Imaging,2016,43(3):574
    14 Gold MR,Sommer T,Schwitter J,et al.Impact of magnetic resonance imaging on ventricular tachyarrhythmia sensing:Results of the Evera MRI Study[J].Heart Rhythm,2016,13(8):1631
    15 Hilbert S,Jahnke C,Loebe S,et al.Cardiovascular magnetic resonane imaging in patients with cardiac implantable electronic devices:a device-dependent imaging strategy for improved image quality[J].Eur Heart J Cardiovasc Imaging,2018,19(9):1 051
    16 Klein-Wiele O,Garmer M,Busch M,et al.Cardiovascular magnetic resonance in patients with magnetic resonance conditional pacemaker systems at 1.5T:influence of pacemaker related artifacts on image quality including first pass perfusion,aortic and mitral valve assessment,flow measurement,short tau inversion recovery and T1-weighted imaging[J].Int J Cardiovasc imaging,2017,33(3):383
    17 Ibrahim EH,Runge M,Stojanovska J,et al.Optimized cardiac magnetic resonance imaging inversion recovery sequence for metal artifact reduction and accurate myocardial scar assessment in patients with cardiac implantable electronic devices [J].World J Radiol,2018,10(9):100
    18 Hong K,Collins JD,Knight BP,et al.Wideband myocardial perfusion pulse sequence for imaging patients with a cardiac implantable electronic devices [J].Magn Reson Med,2019,81(2):1 219
    19 Good ED,Cakulev I,Orlov MV,et al.Long-term evaluation of Biotronik Linox and Linox(smart)implantable cardioverter defibrillator leads[J].J Cardiovasc Electrophysiol,2016,27(6):735
    20 Nielsen JC,Giudici M,Tolasana Viu JM,et al.Safety and effectiveness of a 6-French MRI conditional pacemaker lead:The INGEVITYTM clinical investigation study results[J].Pacing Clin Electrophysiol,2017,40(10):1 121
    21 Mattei E,Gentili G,Gensi F,et al.Impact of capped and uncapped abandoned leads on the heating of an MR-conditional pacemaker implant [J].MagnReson Med,2015,73 (1):390
    22 Higgins JV,Gard JJ,Sheldon SH,et al.Safety and outcomes of magnetic resonance imaging in patients with abandoned pacemaker and defibrillator leads [J].Pacing Clin Electrophysiol,2014,37(10):1 284
    23 邱雯,李小明.植入心脏电子装置后行磁共振检查的安全性 [J].中国心脏起搏与心电生理杂志,2016,30(3):197
    24 Padmanabhan D,Kella DK,Mehta R,et al.Safety of magnetic resonance imaging in patients with legacy with pacemakers and defibrillators and abandoned leads [J].Heart Rhythm,2018,15(2):228