测定水中阴离子合成洗涤剂的标准化操作方法研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Study on the standardized method for determination of anionic synthetic detergent in water
  • 作者:车燕妮 ; 苏秀娟 ; 张凌斐
  • 英文作者:CHE Yan-ni;SU Xiu-juan;ZHANG Ling-fei;Weihai City Center for Diseases Control and Prevention;
  • 关键词:阴离子合成洗涤剂 ; 十二烷基苯磺酸钠 ; 聚丙烯锥形管 ; 涡旋混匀器 ; 标准化操作
  • 英文关键词:Anionic synthetic;;Sodium dodecylbenzene sulfonate;;DBS;;Polypropylene conical tube;;Vortex homogenizer;;Standardized operation
  • 中文刊名:YXWX
  • 英文刊名:Preventive Medicine Tribune
  • 机构:威海市疾病预防控制中心;
  • 出版日期:2019-01-10
  • 出版单位:预防医学论坛
  • 年:2019
  • 期:v.25
  • 语种:中文;
  • 页:YXWX201901028
  • 页数:3
  • CN:01
  • ISSN:37-1428/R
  • 分类号:84-86
摘要
目的建立简单、快速、准确的检测水中阴离子合成洗涤剂的标准化操作方法。方法对国标操作方法进行优化改进,样品量与试剂量按国标法的比例缩减,聚丙烯锥形管替代分液漏斗,涡旋混匀器替代手工振摇,萃取强度均匀稳定,可实现标准化操作。结果标准曲线线性范围为0~1.20 mg/L,线性好(r=0.999 9),重复性好,RSD为1.52%~1.92%;回收率为92.5%~96.9%;标准质控物质测定值在可信范围内。每小时可完成20个样品的测定。结论该法可快速、准确地检测水中阴离子合成洗涤剂,操作极为方便。
        Objective To develop a simple,rapid and accurate standardized method to determinate the anionic synthetic detergent in water. Methods To optimize and improve the operation method of the national standard method,the amounts of samples and reagents were proportional reduced according to the national standard method,liquid funnel was replaced by polypropylene conical tube,manual shaking was replaced by scroll homogenizer,the extraction strength was uniform and stable,which achieved the standardized operation. Results The liner ranged 0-1.20 mg/L,with a good liner and repeatability(r=0.999 9),RSD varied from 1.52% to 1.92%;the recovery rate was 92.5%-96.9%;determination results of MBAs QC sample was in acceptance limits.The determination of 20 samples can be completed in 1 hour. Conclusion The method is rapid and accurate to determinate the anionic synthetic detergent in water,and the operation is extremely convenient.
引文
[1]GB/T 5750.1~5750.13-2006中国标准出版社,2007:56-57.
    [2]刘正丹,江玉姣,徐云斌.二氮杂菲萃取分光光度法测定水中阴离子合成洗涤剂方法的改进[J].中国卫生检验杂志,2008,18(4):724.
    [3]鲁莉,于维森,蒋欣,等.优化亚甲蓝法快速测定饮用水中阴离子合成洗涤剂[J].预防医学论坛,2016,22(1):66-67.
    [4]魏良,张申新,代以春,等.流动注射分光光度法测定环境水中阴离子表面活性剂[J].理化检验,2009,45(9):1 077-1 079.
    [5]韩清,胡讯,徐立,等.LACHATQC8500流动注射测定地表水中阴离子合成洗涤剂[J].中国卫生检验杂志,2012,22(8):1 800-1 801.
    [6]徐燕.流动注射分析水中挥发酚、氰化物及阴离子合成洗涤剂[J].预防医学论坛,2014,20(6):437-439.
    [7]赵莉,崔成祥,张爱萍.亚甲蓝简单快速测定阴离子合成洗涤剂的方法[J].中国卫生检验杂志,2007,17(3):444-445.
    [8]杨丽君,白欣,王小静,等.连续流动分析法测定饮用水中阴离子合成洗涤剂[J].预防医学论坛,2013,19(4):284-285.