摘要
互感器的关键器件之一是λ/4波片。针对不完美λ/4波片对系统的温度补偿作用,阐述了光纤电流互感器的原理,分析了传感环的温度特性,并给出了一组实验验证,实验结果表明,在没有温度补偿算法的情况下,相位延迟约为108°的波片相对于标准的波片对比差变化范围有0.9%的改善,较大地提高了系统的性能。
One of the key components of the transformer is the λ/4 wave plate. Aiming at the temperature compensation of the imperfect λ/4 wave plate to the system, this paper expounded the principle of optical current transformer, analyzed the temperature characteristic of sensing ring and gave a set of experimental verification. The experimental results show that without temperature compensation algorithm, there is 0.9% improvement on ratio error by replacing the standard wave plate with an imperfect λ/4 wave plate which has a phase delay of about 108°, so as to greatly improve the performance of the system.
引文
[1]彭耐.偏振旋转反射干涉式光纤电流传感器及关键技术研究[D].武汉:华中科技大学,2013.
[2]许玲,惠小丽.光学电流传感器的实现方案及其现状[J].大气与环境光学学报,2004,17(1):39-43.
[3]周军,肖恺,李平,等.全光纤电流互感器技术综述[J].信息通信,2015(5):20-21.
[4]魏兵.干涉型光学电流传感器研究[D].杭州:浙江大学,2016.
[5]刘博阳.光纤电流互感器关键状态在线监测技术研究[D].北京:华北电力大学,2017.
[6]胡蓓,叶国雄,肖浩,等.全光纤电流互感器关键状态量及其监控方法[J].高电压技术,2016,42(12):4026-4032.
[7]罗苏南,王耀,丁晔,等.柔性直流输电用±500 k V直流全光纤电流互感器研制及测试[J].高压电器,2017,53(6):48-55.
[8]SHORT S X,TSELIKOV A A,ARRUDA J U D,et al.Imperfect quarter-waveplate compensation in Sagnac interferometer-type current sensors[J].Journal of Lightwave Technology,1998,16(7):1212-1219.
[9]BRANDLE H,NEHRING J,BOHNERT K,et al.Temperature and Vibration Insensitive FiberOptic Current Sensor[J].Journal of Lightwave Technology,2002,20(2):267-276.
[10]YANG Yuanhong.Temperature sensor based on PNRin Sagnac interferometer[J].Chinese Optics Letters,2004,2(5):259-261.
[11]WILLIAMS P A,ROSE A H,DAY G W,et al.Temperature dependence of the Verdet constant in several diamagnetic glasses[J].Applied Optics,1991,30(10):1176-1178.