摘要
针对联合站消防系统设施老化、功能不齐全等问题,对现有的消防系统进行改造。结合最新消防标准和历年的改造经验,通过合理安排施工工序、增设临时工艺、配备消防设施和安全措施的落实,解决了消防罐水量不足、消防功能缺失和施工过程安全风险大等问题,顺利完成了消防系统改造设计的施工。
In view of the aging and incomplete functions of the fire fighting system in the united station, the existing fire fighting system is reformed. According to the latest fire fighting standards and the reform experience over the years, the problems of insufficient water supply of fire tanks, lack of fire fighting function and high safety risk in construction process were solved through reasonable arrangement of construction procedures, addition of temporary technologies, equipping of fire fighting facilities and implementation of safety measures, and the reform design and construction of fire fighting system were successfully completed.