冷成型钢龙骨-石膏板自攻螺钉连接低周往复荷载试验
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Low Cyclic Load Experiment of Cold-formed Steel Self Tapping Screw Connection of Keel-plasterboard
  • 作者:陈伟 ; 陈励纬 ; 陈盛根 ; 张翼东 ; 苏意然 ; 刘彬
  • 英文作者:CHEN Wei;CHEN Li-wei;CHEN Sheng-gen;ZHANG Yi-dong;SU Yi-ran;LIU Bin;Key Laboratory of Building Fire Protection Engineering and Technology of MPS,Tianjin Fire Research Institute of MPS;State Key Laboratory for Geomechanics & Deep Underground Engineering,China University of Mining and Technology;Key Laboratory of C & PC Structures of Ministry of Education,Southeast University;Department of Building Engineering,Zhejiang College of Construction;
  • 关键词:冷成型钢 ; 石膏板 ; 自攻螺钉连接 ; 抗剪性能 ; 低周往复荷载
  • 英文关键词:cold-formed steel;;plasterboard;;self tapping screw connection;;shear performance;;low cyclic load
  • 中文刊名:XBJG
  • 英文刊名:Journal of Architecture and Civil Engineering
  • 机构:公安部天津消防研究所建筑消防工程技术公安部重点实验室;中国矿业大学深部岩土力学与地下工程国家重点试验室;东南大学混凝土及预应力混凝土结构教育部重点实验室;浙江建筑职业技术学院建筑工程系;
  • 出版日期:2018-11-15
  • 出版单位:建筑科学与工程学报
  • 年:2018
  • 期:v.35;No.135
  • 基金:国家自然科学基金青年科学基金项目(51508088);; 江苏省自然科学基金青年基金项目(BK20150605);; 建筑消防工程技术公安部重点实验室开放课题项目(KFKT2015ZD05)
  • 语种:中文;
  • 页:XBJG201806011
  • 页数:6
  • CN:06
  • ISSN:61-1442/TU
  • 分类号:92-97
摘要
开展了冷成型钢龙骨-石膏板自攻螺钉连接抗剪试验研究,完成了32个典型试件低周往复荷载试验,分析了螺钉边距和覆板层数对自攻螺钉连接抗剪强度的影响,并提出了抗剪强度简化公式。结果表明:由于石膏板沿板边与板内方向所具备的抗挤压能力不同,试件正向加载抗剪强度普遍小于负向加载抗剪强度;部分试件在达到抗剪强度峰值后荷载-位移曲线发生突变,此时一般伴随石膏板迅速开裂或者螺钉拔出等现象;试件主要呈现石膏板挤压破坏,部分自攻螺钉存在少量倾斜现象;螺钉边距为10~25mm时,试件抗剪强度随边距增大呈增大趋势;螺钉边距超过25mm时,试件抗剪强度增长不明显;双层覆板试件抗剪强度明显高于单层覆板试件,但尚未达到单层覆板试件抗剪强度的2倍;所提出的抗剪强度简化公式预测结果与试验结果吻合良好。
        The experimental research on the cold-formed steel self tapping screw connection of keel-plasterboard was carried out.The low cyclic load experiments of 32 typical specimens were completed.The influences of screw margin and number of surface plates on the shear strength of self tapping screw connections were analyzed,and the simplified formula of shear strength was put forward.The results show that because of the different anti extrusion abilities of plasterboard along the edge of plate and the inside direction of plate,the shear strength of specimen underpositive load is generally less than that under negative load.The load-displacement curves of some specimens are abrupt after reaching the peak value of shear strength,which is generally accompanied by rapid cracking of plasterboard or bolt pull-out.The specimen mainly presents the extrusion damage of the plasterboard,and some self tapping screws have a small amount of tilts.When the screw margin is 10-25 mm,the shear strength of specimens increases with the increase of margin.When the screw margin exceeds 25 mm,the shear strength of specimens don't increase obviously.The shear strength of double surface plates specimen is significantly higher than that of single surface plate specimen,but has not reached 2 times of that of the single surface plate specimen.The predicted results by simplified formula of shear strength are in good agreement with the test results.
引文
[1]叶继红.多层轻钢房屋建筑结构——轻钢龙骨式复合剪力墙结构体系研究进展[J].哈尔滨工业大学学报,2016,48(6):1-9.YE Ji-hong.An Introduction of Mid-rise Thin-walled Steel Structures:Research Progress on Cold-formed Steel Framed Composite Shear Wall Systems[J].Journal of Harbin Institute of Technology,2016,48(6):1-9.
    [2] FULOP L A,DUBINA D.Design Criteria for Seam and Sheeting-to-framing Connections of Cold-formed Steel Shear Panels[J].Journal of Structural Engineering,2006,132(4):582-590.
    [3] FIORINO L,DELLA CORTE G,LANDOLFO R.Experimental Tests on Typical Screw Connections for Cold-formed Steel Housing[J].Engineering Structures,2007,29(8):1761-1773.
    [4] NITHYADHARAN M,KALYANARAMAN V.Experimental Study of Screw Connections in CFS-calcium Silicate Board Wall Panels[J].Thin-walled Structures,2011,49:724-731.
    [5] PETERMAN K D,NAKATA N,SCHAFER B W.Hysteretic Characterization of Cold-formed Steel Stud-to-sheathing Connections[J].Journal of Constructional Steel Research,2014,101:254-264.
    [6]董军,夏冰青,马宏,等.NAFC、LCFC板及其与轻钢龙骨自攻螺栓连接性能[J].南京工业大学学报,2002,24(5):12-15.DONG Jun,XIA Bing-qing,MA Hong,et al.Researches on NAFC and LCFC Plates and Their Screw Connections with Light-gauge Steel Members[J].Journal of Nanjing University of Technology,2002,24(5):12-15.
    [7]石宇,周绪红,聂少锋,等.冷弯薄壁型钢结构住宅螺钉连接的抗剪性能试验研究[J].建筑结构学报,2010,31(增1):184-188.SHI Yu,ZHOU Xu-hong,NIE Shao-feng,et al.Experimental Investigation on Shear Behavior of Screw Connections in Cold-formed Steel Residential Building[J].Journal of Building Structures,2010,31(S1):184-188.
    [8]李元齐,马荣奎,何慧文.冷弯薄壁型钢与结构用OSB板自攻螺钉连接性能试验研究[J].建筑结构学报,2014,35(5):48-56.LI Yuan-qi,MA Rong-kui,HE Hui-wen.Experimental Study on Behavior of Screw Connections for Coldformed Thin-walled Steel and Structural OSB Boards[J].Journal of Building Structures,2014,35(5):48-56.
    [9]卢林枫,张亚平,方文琦,等.冷弯薄壁型钢自攻螺钉连接抗剪性能试验研究及数值分析Ⅱ:数值分析[J].中南大学学报:自然科学版,2013,44(8):3493-3502.LU Lin-feng,ZHANG Ya-ping,FANG Wen-qi,et al.Experimental Investigation and Numerical Analysis on Shear-bearing Capacity for Self-drilling Screw Connections of Cold-formed Thin-walled SteelⅡ:Numerical Analysis[J].Journal of Central South University:Science and Technology,2013,44(8):3493-3502.
    [10] YE J H,WANG X X,ZHAO M Y.Experimental Study on Shear Behavior of Screw Connections in CFS Sheathing[J].Journal of Constructional Steel Research,2016,121:1-12.
    [11] ROGERS C A,HANCOCK G J.Screwed Connection Tests of Thin G550and G300Sheet Steels[J].Journal of Structural Engineering,1999,125(2):128-136.
    [12] CHEN W,YE J H,CHEN T.Design of Cold-formed Steel Screw Connections with Gypsum Sheathing at Ambient and Elevated Temperatures[J].Applied Sciences,2016,6(9):248-263.
    [13] CHEN W,YE J H,BAI Y,et al.Thermal and Mechanical Modeling of Load-bearing Cold-formed Steel Wall Systems in Fire[J].Journal of Structural Engineering,2014,140(8):A4013002.
    [14] GB 50018—2002,冷弯薄壁型钢结构技术规范[S].GB 50018—2002,Technical Code of Cold-formed Thin-wall Steel Structures[S].
    [15] AISI-S400-15,North American Standard for Seismic Design of Cold-formed Steel Structural Systems[S].