用户名: 密码: 验证码:
体表激光定位可视化干预对单纯胸外按压质量的影响
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:The Effect of Surface Laser Positioning Visual Intervention Model on the Quality of the Chest Compression Alone
  • 作者:曾沛扬 ; 赖志君 ; 谢伟宏 ; 吴苏华 ; 李远华
  • 英文作者:ZENG Pei-yang;LAI Zhi-jun;XIE Wei-hong;WU Su-hua;LI Yuan-hua;Department of ICU , Affiliated Shilong Boai Hospital of Guangdong Medical College;
  • 关键词:可视化干预 ; 单纯胸外按压 ; 质量 ; 影响
  • 英文关键词:visual intervention;;chest compressions alone;;quality;;effect
  • 中文刊名:LNJZ
  • 英文刊名:Lingnan Journal of Emergency Medicine
  • 机构:广东医学院附属石龙博爱医院ICU;
  • 出版日期:2015-08-20
  • 出版单位:岭南急诊医学杂志
  • 年:2015
  • 期:v.20;No.98
  • 基金:广东省东莞市医疗卫生科技计划项目(2014105101217)
  • 语种:中文;
  • 页:LNJZ201504005
  • 页数:3
  • CN:04
  • ISSN:44-1539/R
  • 分类号:14-15+34
摘要
目的:观察体表激光定位可视化干预对单纯胸外按压质量的影响。方法:建立体表激光定位可视化干预模型,将我院急诊、ICU、PICU经系统CPR培训的84名医护人员,随机分为对照组和干预组各42人。两组均对模拟人进行持续的单纯胸外按压4 min,干预组同时要求在体表激光定位装置指示按压深度情况下按压。测量两组入选者双掌叠扣厚度,记录各分钟内按压次数、深度正确的按压次数以及按压前后心率、血压数值。结果:全体入选者双掌叠扣厚度为65.08±6.47 mm,两组各分钟按压频率均达到指南推荐要求,对照组各分钟按压频率及深度正确按压次数在第2 min开始显著下降(P<0.05)。干预组各分钟按压频率无统计学差异(P>0.05),而深度正确的按压次数在第3 min开始显著下降。干预组第3、4 min深度正确的按压次数比较对照组差异有统计学意义(P<0.05);两组按压后心率、收缩压均较按压前显著增高(P<0.05),但组间比较无统计学差异(P>0.05)。结论:体表激光定位干预能有效改善持续单纯胸外按压质量,且不会加剧操作者疲劳。
        Objective :To explore the effect of surface laser positioning visual intervention model on the quality of the chest compression alone. Methods : Surface laser positioning visual intervention model was build. 84 medical staff in the emergency department, ICU and PICU whom had passed CPR training were randomly assigned into intervention group(n =42) and control group(n =42). Both groups carry out chest compressions alone on adult intelligence simulated human for 4 min. The intervention group had to let the skin mark pass the light beam which sent from the laser positioning system. The overlapped palms thickness was measured. The data of pressing frequency, right depth rate(≥ 5 cm) per minute, the heart rate, systolic blood pressure and diastolic blood pressure in pre- and post-CPR were constantly recorded. Results : The overlapped palms thickness of all staff was 65.08 ±6.47 mm. Pressing frequency in both groups can reach recommendation of international guideline, while the pressing frequency, right depth rate per minute of control group had began to decrease significantly by the second minute(P < 0.05). In the intervention group, the frequency was no significant difference among every minute(P > 0.05), and the right depth rate per minute had began to decrease significantly by the third minute(P < 0.05). Compared with the control group,the right depth rate of the intervention group had significant difference in the third and fourth minute(P < 0.05).In both groups, the heart rate, systolic blood pressure decreased significantly pre- and post-CPR(P < 0.05), while there was no significant difference between groups(P > 0.05). Conclusion : Surface laser positioning visual intervention model can improve the quality of the chest compression alone,and can not increase rescuer fatigue.
引文
[1]Field JM,Hazinski MF,Sayre MR,et al.Part 1:executive summary:2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care[J].Circulation,2010,122(18 Suppl 3):640.
    [2]乔晓禹,王吉文,蒋龙元,等.关于医务人员CPR质量的初步研究[J].岭南急诊医学杂志,2010,15(4):249.
    [3]Chung TN,Kim SW,You JS,et al.A higher chest compression rate may be necessary for metronomeguided cardiopulmonary resuscitation[J].Am J Emerg Med,2012,30(1):226.
    [4]张博,穆炜,王炳红,等.心肺复苏中胸外按压的培训及有效性[J].吉林医学,2011,32(8):1652.
    [5]曾沛扬,吴苏华,谢树锋.社区青年成人心肺复苏培训现状及效果分析[J].岭南急诊医学杂志,2013,18(6):426.
    [6]陈昌卫,李恒,黄子通,等.遵循高质量胸外按压标准对操作者客观疲劳度的影响[J].中国医药科学,2013,3(7):16.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700