变温热源驱动非共沸混合工质ORC换热器温度匹配性能评价方法
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:A Method to Evaluate Temperature Matching Performance of Heat Exchanger in Variable-Temperature Heat Source Driving ORC with Zeotropic Refrigerant Mixtures
  • 作者:王辉涛 ; 王华 ; 葛众 ; 陈蓉 ; 黄峻伟
  • 英文作者:WANG Hui-tao;WANG Hua;GE Zhong;CHEN Rong;HUANG Jun-wei;Faculty of Metallurgical and Energy Engineering,Kunming University of Science and Technology;
  • 关键词:有机朗肯循环(ORC) ; 非共沸混合工质 ; 熵产 ; 效率 ; 温度匹配
  • 英文关键词:Organic Rankine Cycle;;zeotropic refrigerant mixture;;entropy generation;;exergy efficiency;;tem-perature match
  • 中文刊名:KMLG
  • 英文刊名:Journal of Kunming University of Science and Technology(Natural Science Edition)
  • 机构:昆明理工大学冶金节能减排教育部工程研究中心;
  • 出版日期:2014-02-15
  • 出版单位:昆明理工大学学报(自然科学版)
  • 年:2014
  • 期:v.39;No.188
  • 基金:国家自然科学基金项目(51066002,51366005);; NSFC-云南联合基金项目(U0937604);; 云南省重大产业技术开发专项项目(2008CD001);; 云南省科技强省计划项目(2008KA002)
  • 语种:中文;
  • 页:KMLG201401012
  • 页数:6
  • CN:01
  • ISSN:53-1223/N
  • 分类号:64-68+77
摘要
在对变温热源驱动非共沸混合工质ORC(有机朗肯循环)换热器中冷热流体温度匹配性能分析的基础上,提出了用于评价非共沸混合工质ORC换热器中冷热流体间温度匹配性能的指标DMPC(温度匹配指标的标准偏差).采用该指标对换热过程进行所得的结果与采用热力学第二定律的分析结果具有一致性,即当指标DMPC增大,换热器中的额外熵产增加,效率升高,而当指标DMPC减少,换热器中的额外熵产降低,效率下降.该评价指标还可作为优化非共沸混合工质ORC换热器中冷热流体温度匹配性能的目标函数,便于进行变温热源驱动ORC非共沸混合工质的组元匹配及配比优化.
        Based on the analysis of the temperature matching performance of the heat exchanger between two fluids in variable-temperature heat source driving ORC( Organic Rankine Cycle) with zeotropic refrigerant mixtures, a new criterion DMPC( Standard deviation of temperature matching index) is proposed to evaluate the overall quality of temperature match between two fluids across the heat exchanger. The results deduced by the proposed criterion are consistent with that deduced by the second law,i. e,as the criterion DMPC goes up,the unnecessary entropy generation will increase,while the exergy efficiency of the heat exchanger will decline,and vice verse. This criterion can also be adopted to be the optimization objective for getting a better temperature match between the two heat transfer fluids in heat exchanger.
引文
[1]王华,王辉涛.低温余热发电有机朗肯循环技术[M].北京:科学出版社,2010.
    [2]Mulroy W J,Domanski P A,Didion D A.Glide matching with binary and ternary zeotropic refrigerant mixtures Part 1:An experimental study[J].International journal of refrigeration,1994,17(4):220-225.
    [3]Domanski P A,Mulroy W J,Didion D A.Glide matching with binary and ternary zeotropic refrigerant mixtures Part 2:A computer simulation[J].International journal of refrigeration,1994,17(4):226-230.
    [4]Richardson R N,Butterworth J S.The performance of propane/isobutane mixtures in a vapor-compression refrigeration system[J].Int J Refrig,1995,18(1):58-62.
    [5]Swinney J,Jones W E,Wilson J A.The impact of mixed non-azeotropic working fluids on refrigeration system performance[J].Int J Refrig,1998,21(8):607-616.
    [6]Somchai Wongwises,Amnouy Kamboon,Banchob Orachon.Experimental investigation of hydrocarbon mixtures to replace HFC-134a in an automotive air conditioning system[J].Energy Conversion and Management,2006,47(11-12):1644-1659.
    [7]Gianfranco Angelino,Piero Colonna Di Paliano.Multicomponent working fluids for organic Rankine cycles(ORCs)[J].Energy,1998,23(6):449–463.
    [8]Peng D Y,Robinson D B.A new two-constant equation of state[J].Industrial&Engineering Chemistry Fundamentals,1976,15(1):59-64.
    [9]Steven Brown J.Predicting performance of refrigerants using the Peng-RobinsonEquation of State[J].International Journal of Refrigeration,2007,30(8):1319-1328.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700