摘要
以天津市某污水厂为对象,在不增加占地的前提下,通过A~2/O+A/O工艺技术改造、新建浸没式超滤膜单元等方式,对原有的"A~2/O+混凝沉淀+纤维转盘滤池"处理工艺进行了提标改造。运行结果表明,改造后的系统出水有较大幅度提升,COD_(Cr)、BOD_5、SS、TN、TP等各项指标均可稳定达到天津市《城镇污水处理厂污染物排放标准》(DB 12/599—2015) A标准要求。
Taking a wastewater treatment plant in Tianjin as a case,the original treatment process of A~2/O + coagulation + sedimentation + rotating fibre filter was upgraded and renovated,by means of A~2/O + A/O technological transformation and new submerged UF membrane unit without increasing land occupation. The operational results showed that the effluent of the renovated system had been greatly improved,and indicators such as COD_(Cr),BOD_5,SS,TN,TP could steadily meet the requirements of level A of Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant( DB 12/599—2015).
引文
[1]卢如,巨志剑,杜琼,等.采用A/O工艺的污水处理厂提标改造工程设计[J].中国给水排水,2018,34(20):56-59.
[2]王立东,王阿华.污水处理厂提标改造措施选择与工程实践[J].中国给水排水,2010,26(8):30-32,36.
[3]胡维杰.上海市石洞口污水处理厂提标改造方案探讨[J].中国给水排水,2014,30(2):44-47.
[4]钟昊亮.深圳市污水处理厂提标改造生产保障措施[J].中国给水排水,2018,34(24):26-31.
[5]李稳,宋伟,董良飞,等.太湖流域某化工园区污水厂提标改造工程实践[J].中国给水排水,2014,30(22):129-132.