///Stability and accuracy for determination of δ13C of polycyclic aromatic hydrocarbons(PAHs)were tested by gas chromatography-combustion-isotope ratio mass spectrometry(GC-C-IRMS)with continuous and intermittent injection modes. The results showed that the peak area and peak separation degree were the main factors influencing the precision of δ13C data. The fractionation of stable carbon isotopes of PAHs during the sample pretreatment processes was also tested. The cleanup process with gel permeation chromatography (GPC), silica gel column, as well as rotatory evaporation, nitrogen purge and other enrichment process brought no significant isotope fractionation of PAHs. Isotope fractionation in cleanup processes with silica gel column was little larger than with GPC, but still within two standard deviation range of the mean δ13C of PAHs from an unprocessed standard material. And the enrichment processes of rotatory evaporation and nitrogen purge produced a little isotope fractionation for all the measured δ13C of PAHs within 1σ range of the mean δ13C from the unprocessed standard material.