Determination of Hf, Ti and Zr in Zirconium-Titanium Placer by Inductively Coupled Plasma-Atomic Emission Spectrometry
详细信息   
摘要


     Zirconium titanium placer is an ore which is extremely difficult to be digested.It is almost insoluble in all kind of acid except HF.Moreover,Hf,Ti and Zr in the ore tends to hydrolyze to form insoluble partial hafnium acid,metatitanic acid and zirconium hydroxide which increases the difficulty for their qualitative determination.The traditional chemical method can only yield total amounts of Zr and Hf and involve a complex time-consuming chemical procedure.After comparing four different methods to melt the sample,it was found that extracting salt with HNO3-EDTA and melting the sample with Na2 O2 at 700tin; mso-fareast-font-family: 宋体; mso-fareast-theme-font: minor-fareast; mso-hansi-font-family: calibri; mso-hansi-theme-font: minor-latin"> was a simple,highly efficient and practical method for sample digestion.Based on this melting method,an Inductively Coupled Plasma-Atomic Emission Spectrometry tin; mso-fareast-font-family: 宋体; mso-fareast-theme-font: minor-fareast; mso-hansi-font-family: calibri; mso-hansi-theme-font: minor-latin">ICP-AEStin; mso-fareast-font-family: 宋体; mso-fareast-theme-font: minor-fareast; mso-hansi-font-family: calibri; mso-hansi-theme-font: minor-latin"> method was set up for Hf,Ti and Zr detection in zirconium titanium placer.Re was used as an internal standard and high frequency power was applied to eliminate the matrix effect.The RSD tin; mso-fareast-font-family: 宋体; mso-fareast-theme-font: minor-fareast; mso-hansi-font-family: calibri; mso-hansi-theme-font: minor-latin">n =11tin; mso-fareast-font-family: 宋体; mso-fareast-theme-font: minor-fareast; mso-hansi-font-family: calibri; mso-hansi-theme-font: minor-latin"> was less than 1.3tin; mso-fareast-font-family: 宋体; mso-fareast-theme-font: minor-fareast; mso-hansi-font-family: calibri; mso-hansi-theme-font: minor-latin"> and the detection limits for Hf,Ti and Zr were 0.97,0.86 and 0.33 μg/g,respectively.The results were much more precise and accurate than the traditional chemical method and X-ray Fluorescence Spectrometry.The method of melting the sample in a corundum crucible increased the number of samples and reduced the cost,which is beneficial for the fast determination of insoluble Zr-Ti placer samples.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700